Winner 2009 particle size analyzer Winner 2009 particle size analyzer
Next

Winner 2009 particle size analyzer

13598 ~ 28598 USD / Set

|

1 Set Minimum Order

País:

China

N º de Modelo:

Winner 2009A / Winner 2009B

Precio FOB:

13598 ~ 28598 USD / Set Obtener el precio más reciente

Lugar de origen:

China shandong

Precio de pedido mínimo:

13598 per Set

Cantidad de pedido mínimo:

1 Set

Detalle de embalaje:

The laser particle size analyzer package is plywood box

El tiempo de entrega:

5 to 15 days

Capacidad de suministro:

500 Set per Month

Tipo de pago:

T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal

Contactar ahora
Miembro Básico

Persona de contacto Ella

Unit 2 East Building F North District University Science and Technology Park, No 750 Shunhua Road Li, Jinan, Shandong

Contactar ahora

Especificaciones del producto

  • Standard::GB/T 19627-2005/ISO 13321:1996 GB/T 29022-2012/ISO
  • Measure range::0.01μm-2000μm/0.01μ
  • Accuracy error::<0.5%
  • Repeatability error::<0.5%
  • Light source::Semiconductor laser
  • Detector::Imported Japan HAMAMATSU photo-multiplier (19-90℃)

Descripción del producto

产品描述
Winner***9A/Winner***9B全自动湿式激光粒度分析仪采用MIE散射原理,测量粒度从0.*1μm到***0μm,为各种应用提供可靠、可重复的粒度分析。它采用双光束和多光谱检测系统和侧面光散射测试技术显着提高了测试精度和性能,代表了国内该领域的先进水平。
 
主要特点
 
(1)Winner Patent -Optical path design
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design make its precision achieves from 0.*1μm to ***0μm/***0μm,and Dual-laser orthogonal light make use of the semiconductor auxiliary laser extend the test angle from *5 degree to **5 degree, ensure receive all the angles of signals.

(2) Expand Size Range
Winner***8A/B measurement range significantly expanded to 0.*1μm, particularly suitable for small samples of the user, the sub micron particle test results reached the international level

(3)Full automatic built-in wet dispersion system
The ultrasonic dispersion, mechanical stirring and circulation channel reasonable integrated in the interior of the instruments, ensure the uniform dispersion and distribution of particles in the testing process, effectively avoid uneven distribution, large particle deposition phenomenon caused by long pipe line of outside dispersion system , to ensure the accuracy of the test results.

(4) Intelligent Operation mode
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all processes including water-supply, dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.

(5)Automatic Optical path alignment system

The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.*1μm, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.

(6)Authoritative calibration method
In the entire test range using the national standard materials for calibration, only a year calibration once the instrument can. Calibration method is simple and quick.

(7) Unconstrained free fitting patent technique

Winner original unconstrained free fitting patent technology, particle size analysis is not affected by any functional constraints, truely refelect particle size distribution.
Specification
Model Name
Winner***9A
Winner***9B
Standard
ISO******1:***9, GB/T****7.*****8, Q/JWN*******9
Principle
MIE scattering principle
Measuring Range
0.*1μm****0μm
0.*1μm****0μm
Channels Number
**7
**0 (different photo detectors & optical light path)
Accuracy error
≤0.5% (Deviation of D*0 on national standard sample)
Repeatability error
≤0.5% (Deviation of D*0 on national standard sample )
Light source
High performance He-Ne Laser (λ= **2.8nm, P>2MW)
Lifetime>****0hours

Dispersion
Method
Ultrasonic
Frequency:*0KHz Power:*5W, Time: ≥1S ,Anti-dry function
Stir
Revolutions Speed: *****0RPM (Adjustable)
Circulate
Rated Flow:8L/min Rated Power:*0W
Sample Pool
Volume:**0mL
Micro-
Sample Pool
Volume: *0mL ( Available)
Operation Mode
Full automatic/ manual control, freely choose
Resolution
Free distribution truly reflect particle size distribution
Optical bench alignment system
Japan Canon lens, Full automatic,precision is up to 0.1um
Software function
Analysis mode
自由分布、RR分布、对数正态分布、网格数分类等
统计方法
数量分布、数量分布
统计比较
样品多次检测结果
不同批次样品检测结果、
加工前后样品检测结果、
不同时间样品检测结果。
用户自定义分析
按粒径计算百分比 按
百分比计算粒径
按粒径范围计算百分比
满足不同行业颗粒测试表征要求
测试报告

País: China
N º de Modelo: Winner 2009A / Winner 2009B
Precio FOB: 13598 ~ 28598 / Set Obtener el precio más reciente
Lugar de origen: China shandong
Precio de pedido mínimo: 13598 per Set
Cantidad de pedido mínimo: 1 Set
Detalle de embalaje: The laser particle size analyzer package is plywood box
El tiempo de entrega: 5 to 15 days
Capacidad de suministro: 500 Set per Month
Tipo de pago: T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal
Grupo de productos : wet laser particle size analyzer

Send a direct inquiry to this supplier

A:

Ella < Jinan Winner Particle Instrument Stock Co., Ltd. >

quiero saber: