¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Winner 2005 particle size analyzer Winner 2005 particle size analyzer Winner 2005 particle size analyzer Winner 2005 particle size analyzer Winner 2005 particle size analyzer
Next

Winner 2005 particle size analyzer

8998 ~ 18998 USD / Set

|

1 Set Minimum Order

País:

Taiwan

N º de Modelo:

Winner 2005A / Winner 2005B

Precio FOB:

8998 ~ 18998 USD / Set Obtener el precio más reciente

Lugar de origen:

China shandong

Precio de pedido mínimo:

8998 per Set

Cantidad de pedido mínimo:

1 Set

Detalle de embalaje:

The laser particle size analyzer package is plywood box

El tiempo de entrega:

5 to 15 days

Capacidad de suministro:

500 Set per Month

Tipo de pago:

-

Contactar ahora
Miembro Básico

Persona de contacto Ella

Unit 2 East Building F North District University Science and Technology Park, No 750 Shunhua Road Li, Jinan, Shandong

Contactar ahora

Especificaciones del producto

  • Size Range::::0.01μm/0.1μm-1000μ
  • Standard::::ISO13320-1:1999,GB/T19077.1-2008, Q/0100JWN001-
  • Channels Number::::40 pcs
  • Accuracy error::::<1%
  • Repeatability error::::<1%
  • Light Source::::He-Ne laser

Descripción del producto

Product Description
Winner***5A/B intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.*1/0.1μm to ***0μm. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data,built-in side wide-angle detector, make sure get 0.*1 micron particles scattering angles.
 
Main Features
 
(1) Light path: Adopt converging light Fourier transform light path,measure range expanded from 0.*1μm****0μm.

(2)Intelligent full automatic operation mode realize one key test, automatically supply water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.

(3) Automatic Optical path alignment System,
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.*1μm, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.

(4)Full built-in Sample dispersion system,
Auto wet dispersion system,SOP realize one key operation.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, it guarantees the representativeness of test result.

(5) Analysis software:adopt unconstrained free fitting patent technology make particle analysis not be restricted by any functions, truly reflect particle size distribution.

(6) High sensitive photo detectos gathering all the particles scattering signals, ensure the good accuracy.

(7)Output parameters:(D*0, D*3, D*6, D*0, D*6, D*5, D*5, D*4, D*0, D*7,D*8,set any value, S/V, D[3,2],D[4,3] )
Specification
Model Name
Winner***5A/Winner***5B
Standard
ISO******1:***9,GB/T****7.*****8,Q/***0JWN*******3
Principle
MIE Scattering Principle
Size range
0.*1μm****0μm/0.1μm****0μm
Photodetectos
*0pcs/*7 pcs
Accuracy
≤0.5% (Deviation of D*0 on national standard sample)
Repeatability
≤0.5% (Deviation of D*0 on national standard sample)
Laser
Semi conductor Laser λ= **6.5nm, p>2mW
Service time>****0 hour
Wet dispersion
Ultrasonic
Frequency:*0KHz Power:*5W, Time: ≥1S
Agitator
Revolutions Speed: *****0RPM (Adjustable)
Circulation
Rated Flow:8L/min Rated Power:*0W
Sample tank
Volume: **0mL
Operation mode
Manual and Full automatic
Optical alignment system
Full automatic optical path alignment system
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Report Items
Particle size distribution table&graph, average diameter, Median diameter, SSA, etc.
Testing speed

País: Taiwan
N º de Modelo: Winner 2005A / Winner 2005B
Precio FOB: 8998 ~ 18998 / Set Obtener el precio más reciente
Lugar de origen: China shandong
Precio de pedido mínimo: 8998 per Set
Cantidad de pedido mínimo: 1 Set
Detalle de embalaje: The laser particle size analyzer package is plywood box
El tiempo de entrega: 5 to 15 days
Capacidad de suministro: 500 Set per Month
Tipo de pago: -
Grupo de productos : wet laser particle size analyzer