UNT-EAP Intelligent Electric Arc Protection System
Next

UNT-EAP Intelligent Electric Arc Protection System

500 ~ 10000 USD / Set ( Negotiable )

|

1 Set Minimum Order

País:

China

N º de Modelo:

UNT-EAP

Precio FOB:

500 ~ 10000 USD / Set ( Negotiable ) Obtener el precio más reciente

Lugar de origen:

Hebei Province,China

Precio de pedido mínimo:

500 per Set

Cantidad de pedido mínimo:

1 Set

Detalle de embalaje:

as customers' requirements

El tiempo de entrega:

more or less 20 days

Capacidad de suministro:

500 Set per Month

Tipo de pago:

T/T, L/C, Other

Grupo de productos :

-

Contactar ahora
Miembro Básico

Persona de contacto Christina

Baoding, Hebei

Contactar ahora

Especificaciones del producto

  • Action export :less than 7 ms
  • Application four:Rectifier cabinet protection
  • Application two:Feeder cable connector protection
  • system components:main unit, acquisition unit, etc.
  • Application three:Box-type substation protection
  • Application one :medium and low-voltage busbar protection in switchgear

Descripción del producto

Overview:
On the basis of long-term electrical automation product research and design, the Intelligent Arc Protection System is a new generation of intelligent arc protection system by importing advanced technology abroad. 

Main Application
●  Medium and low voltage busbar protection in switch cabinet
●  Box-type transformer substation protection
●  Rectifier cabinet protection
●  Feeder cable connector protection

Considering there is arc when faults happen inside the cabinet and the principle of lockout after over current, UNT designed and researched the UNT-EAP intelligent arc protection system with characters of fast, reliable, simple system configuration and strong adaptability, it is an ideal busbar protection solution.

UNT-EAP intelligent arc protection device can connect to several arc signal and current signal from the arc sensor. The arc sensor can be placed in any position of the switchgear; it is normally installed in switchgear compartment or along the busbar. The main action is on the basis of two different elements when there is a fault: arc and current increment. When the device detects the certain arc and current increment, it sends the trip commend and displays the position of the fault.

Contrast with Characteristics of Similar Products at Home and Abroad
 

No. Technical Points UNT-EAP Similar Products at Home and Abroad
1 System components The main unit is of an integrated design, suitable for loop separate installation. Composed by the master control, arc, current, power and other modules, with complicated design and installation and low reliability.
Independent acquisition unit
2 Fault positioning Apart from communication, each arc corresponds to a relay output to achieve the fault hard positioning The fault positioning is achieved only by communication.
3 Arc signal The serial transmission is used and the detection point can be infinitely extended. The parallel way is adopted and the detection points are restricted for several times at the point.
4 Human machine interface Large-screen LCD, Chinese menu, friendly interface, easy to operate Indicator light, digital tube or display in English
5 Parameter settings All settings are operated on the LCD interface, which are accurate and simple, with high reliability. The code-dial switch or mechanical knob is used, with low accuracy and vibration and wear as well as other hidden hazards.
6 Communication networking Two ways of communication interfaces are provided. It supports *@********************IEC**3, IEC**4 and many other communication protocols. Single communication interface and supporting protocol

Products Components:
UNT-EAP****0 the main unit of arc protection
The main unit is the core component of the arc protection system, and it is responsible for acquisition, measurement, calculation and logical judgment of the s to achieve the protection logic of the system, communication with monitoring system, self-test and other auxiliary functions.

UNT-EAP****0 Arc Acquisition unit
As the arc protection acquisition unit, the unit provides 8 s and 8 outputs arc acquisition, it collects arc by the detector and sends signal to the main unit by optical fiber and there is a communication port for data transmission to the main unit . When there are more than one acquisition unit, each acquisition unit transmits arc signal by series method, and transmit to the main unit finally.

UNT-EAP****0 Rectifier cabinet acquisition unit
As the rectifier cabinet acquisition unit, it collects arc by the light band method, and sends signal to the main unit by optical fiber and there is a communication port for data transmission to the main unit. When there are more than one acquisition unit, each acquisition unit transmits arc signal by series method, and transmit to the main unit finally.

UNT-EAP****0 Feeder protection unit
As the feeder line type arc protection unit, it is independently used as feeder-type arc protection, each unit provides 3 s of the arc acquisition and collects arc by the detector. When producing arc in feeder cabinet, the feeder protection unit trips the breaker in feeder cabinet.

Functions & Features
●  Embedded high-speed **-bit microprocessor 

●  With large- screen LCD, friendly interface and easy operating

●  The key components are imported. 

●  The unit takes unique fast current algorithm, which guarantees the reliability of current criterions with calculating time less than 2ms.

●  With the functions of hard-positioning and soft-positioning to failure

●  The arc signal can be transmitted serially among the acquisition units to arbitrarily increase the number of monitoring points and greatly reduce the cost of the transmission optical fiber. 

●  Build-in power module and current acquisition module, easy to install and use, high reliability. 

●  There are optical fiber and communication connection between the main unit and acquisition unit; it can transmit the arc signal of the failure and the other datas.

●  Setting parameters do not need mechanical components including decimal code switches and potentiometers with full-digital, high precision, no-vibration and wear.

●  Flexible networking solutions reached by variety of communication ports.

●  Optional current protection with delay function, which can be secondary over-current protection of the switch cabinet


 

País: China
N º de Modelo: UNT-EAP
Precio FOB: 500 ~ 10000 / Set ( Negotiable ) Obtener el precio más reciente
Lugar de origen: Hebei Province,China
Precio de pedido mínimo: 500 per Set
Cantidad de pedido mínimo: 1 Set
Detalle de embalaje: as customers' requirements
El tiempo de entrega: more or less 20 days
Capacidad de suministro: 500 Set per Month
Tipo de pago: T/T, L/C, Other
Grupo de productos : -

Send a direct inquiry to this supplier

A:

Christina < Baoding UNT Electric Co., Ltd. >

quiero saber: