¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Temperature and humidity sensor(RJ45) Temperature and humidity sensor(RJ45) Temperature and humidity sensor(RJ45)
Next

Temperature and humidity sensori¼ˆRJ45i¼‰

45 ~ 60 / Piece

|

10000 Piece Minimum Order

País:

China

N º de Modelo:

XW-210

Precio FOB:

45 ~ 60 / Piece Obtener el precio más reciente

Lugar de origen:

China

Precio de pedido mínimo:

45 per Piece

Cantidad de pedido mínimo:

10000 Piece

Detalle de embalaje:

box, temperature monitor

El tiempo de entrega:

7 to 14 days

Capacidad de suministro:

10000 Piece per Month

Tipo de pago:

Other, PayPal, D/P, L/C, T/T

Grupo de productos :

-

Contactar ahora
Miembro Básico

Persona de contacto Mr. Steven

DaLang, Shenzhen, Guangdong

Contactar ahora

Especificaciones del producto

  • Sensitive measured values:RS485 Interface

Descripción del producto

XW***0 temperature and humidity sensor adopts the latest precision technology semiconductor sensitive device design program, used to measure the temperature, humidity of the indoor environment of the integrated intelligent monitoring module. The product not only has the characteristics of intuitive display, high precision, low cost, beautiful appearance, convenient installation, but also has special self-recovery and self-calibration functions. XW***0 temperature and humidity sensor output alarm signal, RS**5 transmission can be integrated with various monitoring systems to achieve remote control.

 

 

1.product characteristics

• With self-recovery self-correction function, high precision and good consistency.

• Unique air duct design, anti-electromagnetic interference design, prevent the circuit temperature from affecting the sensor accuracy.

• With temperature and humidity error correction settings for easy periodic calibration.

• Large-screen high-brightness LCD display, intuitive observation, easy operation.

• With temperature unit selection: Celsius (°C), Fahrenheit (°F) can be set and used worldwide.

• With RS**5 interface, using standard MODBUS protocol to facilitate remote monitoring system integration.

• Modular structure, terminal type and RJ*5 interface wiring are optional, easy installation and maintenance.

2.technical parameters

Monitoring area - ****0m2

Size —— *0**0**5mm

Temperature range - **0°C to *0°C

Humidity range - 0 to **0% RH

Temperature accuracy - error < ± 0.3 °C, tested at *5 °C.

Humidity accuracy - error <±3%RH, tested at *5°C.

Power Requirements - *2VDC

Communication Interface - RS**5

Baud rate - default ***0; optional ***0, ***0, ***0 bit/s, data format N,8,1;

Communication Protocol - MODBUS-RTU Protocol

3.the operating instructions

Installation position

XW***0 temperature and humidity sensor can be installed indoor wall, ceiling ceiling installation.

wiring

The XW***0 temperature and humidity sensor is electrically connected to the outside through two RJ*5 connectors. The RJ*5 connector is used for power supply, communication, and device cascading. At the same time reserved the terminal, inconvenient to use the network cable can be connected through the terminal.

The XW***0 temperature and humidity sensor provides power supply and RS**5 output interface. When connecting, V+ is connected to the positive terminal of the power supply, V- is connected to the negative terminal of the power supply, D+ is connected to RS**5 positive, and D- is connected to RS**5 negative.

Precautions

a. During the installation, the terminal of the slot is connected to the sensor base, and the transition of the PVC terminal head is applied. In order to ensure that the slot and the sensor are installed on the same axis, it is recommended that the base be installed first and then in the slot.

b. The horizontal distance from the sensor to the air-conditioning air outlet should be greater than 1.5m, and the distance from the ceiling air-supply outlet should be greater than 0.5m.

Fourth, debugging

After all the wiring steps of the XW***0 temperature and humidity sensor are completed, the following instructions can be used for debugging.

MENU : Press to enter the setting interface and exit interface (quit).

â–³ : Setting mode: Turn up the function and increase the setting value;

â–½ : Setting mode: Flip down function and increase setting value

ENTER: Confirm the setting value.

País: China
N º de Modelo: XW-210
Precio FOB: 45 ~ 60 / Piece Obtener el precio más reciente
Lugar de origen: China
Precio de pedido mínimo: 45 per Piece
Cantidad de pedido mínimo: 10000 Piece
Detalle de embalaje: box, temperature monitor
El tiempo de entrega: 7 to 14 days
Capacidad de suministro: 10000 Piece per Month
Tipo de pago: Other, PayPal, D/P, L/C, T/T
Grupo de productos : -

Productos relacionados Shenzhen Xiangwei Measurement and control Technology co LTD

Send a direct inquiry to this supplier

A:

Mr. Steven < Shenzhen Xiangwei Measurement and control Technology co LTD >

quiero saber: