Precio FOB
Obtener el precio más reciente20 ~ 21 USD / Piece
|10 Piece Minimum Order
País:
China
N º de Modelo:
SF-104T
Precio FOB:
20 ~ 21 USD / Piece Obtener el precio más reciente
Lugar de origen:
Zhongshan,Guangdong,China
Precio de pedido mínimo:
20 per Piece
Cantidad de pedido mínimo:
10 Piece
Detalle de embalaje:
Standard export packaging
El tiempo de entrega:
15 working days
Capacidad de suministro:
20000 Piece per Month
Tipo de pago:
Western Union, T/T
Grupo de productos :
Persona de contacto Ms. Miu
No.2, Huashi Road, Gangkou Town, Zhongshan, Guangdong 528400, China, Zhongshan, Guangdong
Features
Mini-sized and integrated
intelligent control and applicable to the compressor of one HP.
(Include 1HP)
Temperature Display/ Temperature
Control/ Manual, automatic defrost /Evap. Fan Control/
Electric heat, hot gas defrost/
Time, temp setting to end defrost/
High, low temperature
alarm/Value StoringSelf Testing
Technical data
Temperature sensor: NTC, Double
sensors(for cold room temp.&defrost control), 2m(L)
Range of temperature displayed :
—*5~*5℃ (ï¼*5~**0℉)
Accuracy:
±1℃(±2℉)
Range of set temperature:
—*5~*5℃ (ï¼*0~**0℉)
Factory default :
0℃(*2℉)
Output contact
capacity:
Compressor: N. O.
*0A/**0VAC
(applicable to 1 HP compressor,
if more it needs to connect an AC contactor)
Defrost: N.O.*0A/**0VAC
(applicable to 1KW load, if more it needs to connect AC
contactor)
Evap. Fan: N. O. 5A/**0VAC
Parameters
Parameter | Function | Set range | Default |
E1 | Lower set point limit range |
ï¼*0℉ ï¼*5℃~Set temp. |
ï¼*1℉ ï¼*5℃ |
E2 | Higher set point limit range |
**0℉ *5℃~Set temp. |
*8℉ *0℃ |
E3 | Temp. hysteresis |
1~*8 ℉ 1~*0℃ |
7℉ 4℃ |
E4 | Comp. Start delay time | 0~*0min | 2min |
E5 | Offset on room temp. | ï¼5~5 ℉ï¼â„ƒ | 0 |
E6 | Offset on evap. Temp. | ï¼5~5 ℉ï¼â„ƒ | 0 |
F0 | Defrost type |
0=Electric
heat 1=Hot gas |
0 |
F1 | Max. Defrost duration | 1~*0 min | *0min |
F2 | Defrost interval time | 0~*4hr | 6hr |
F3 | Defrost termination temp. |
*2~*8 ℉ 0~*0℃ |
*6℉ 8℃ |
F4 | Display during defrost |
0=Normal
display 1 = Last value before defrost |
0 |
F5 | Fan control |
0=Parallel with
comp. 1 = Continuous running (except when defrost) |
0 |
C1 | Temperature unit |
0=Celsius 1=Fahrenheit |
0 |
C2 | High temperature alarm |
ï¼*0~0℃/℉(relative to set temp. Set value) |
*0 |
C3 | Low temperature alarm |
ï¼*0~0℃/℉(relative to set temp. Set value) |
**0 |
C4 | Alarm delay time | 1~*0 Min | *0Min |
País: | China |
N º de Modelo: | SF-104T |
Precio FOB: | 20 ~ 21 / Piece Obtener el precio más reciente |
Lugar de origen: | Zhongshan,Guangdong,China |
Precio de pedido mínimo: | 20 per Piece |
Cantidad de pedido mínimo: | 10 Piece |
Detalle de embalaje: | Standard export packaging |
El tiempo de entrega: | 15 working days |
Capacidad de suministro: | 20000 Piece per Month |
Tipo de pago: | Western Union, T/T |
Grupo de productos : | thermostat for refrigeration |