¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
K-3837 Ground Fault Locator / Ground Fault Detector - Kongter
Next

K-3837 Ground Fault Locator / Ground Fault Detector - Kongter

|

- Minimum Order

País:

China

N º de Modelo:

K-3837 Ground Fault Locator

Precio FOB:

Lugar de origen:

-

Precio de pedido mínimo:

-

Cantidad de pedido mínimo:

-

Detalle de embalaje:

-

El tiempo de entrega:

-

Capacidad de suministro:

-

Tipo de pago:

-

Grupo de productos :

-

Contactar ahora
Miembro Básico

Persona de contacto Diana

Langshan Road, Shenzhen, Guangdong

Contactar ahora

Descripción del producto

Bad insulation or grounding in the power system is a very big hazard and it can be very costly to repair upon power break-off. Therefore, it will be very significant to fast pinpoint and elimination of grounding faults. It is also required by DIN VDE *******0 (VDE *******0): ******6 chapter **1.6.3.1 and IEC *********1 chapter **3.1.5.4. 
 
Kongters K****7 is developed to fast detect, trace and pinpoint virtual grounding faults on DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. This device is widely used in different DC systems including power utilities, locomotive, telecom and etc.
 
Features
- Safe to use
It could quickly pinpoint the ground fault without injecting signal to DC system. There is no interruption to DC system itself during signal fault location with its built-in model for current and voltage limitation.
- High reliable designing
It adopts main system of **-bit micro-processor. Hardware designing strictly follows EMC standard to ensure reliability of itself and its tested systems.
- Precise measurement
It adopts high accurate current clamp for signal tracing and precise ADC for voltage sampling. This ensures the accurate measurement of voltage and resistance.
- User-friendly interface
It has LCD display with vivid information indicating grounding status, waveform, insulation leveling, insulation resistance, leakage current, and direction of ground fault and so on. This user-friendly interface makes it easy and effective to use onsite.  
- Intelligent measurement function
。Signal analyzer can automatically identify system voltage leveling.
。When insulation resistance has any change, signal analyzer could quickly indicate the changes.
。Distance will not affect the signal detection once the signal analyzer and detector are synchronized.
。During fault location, current clamp could either clamp on single cable or multiple cables for faster and more effective signal tracing.
。Signal detector will indicate the direction of ground fault on screen once it detects any insulation problem.
。Complete measurement and trouble-shooting function
。Signal detector and analyzer have wireless communication. Complete measurement and info displaying function could handle different types of insulation problem in DC system.
 
Application
。Railway and Transit: signal, communication, and locomotive electric equipment
。Power Utility: DC system with faulty grounding
。Industrial Facilities: electric safety equipment for general power distribution applications
。Telecommunication: electronic equipment with faulty grounding
 
Functions
。Measures voltage between DC system and ground ranging from 0 to **0V.
。Measures grounding resistance up to **9KΩ for both busbars and each branch circuit
。It detects and measures AC voltage which interrupts in DC system. Detection range is from 0 to **8V.
。Fast signal positioning for the point of ground fault in branch circuit.
。It performs the function as accurate current meter with resolution up to 0.*1mA.
。It could quickly pinpoint the ground fault without injecting signal to DC system.
。Arrow indication effectively helps users trace the signal and pinpoint the ground fault.
。Display of insulation index after signal detection on each tested branch circuit.
。Waveform display for tested circuit, indicating insulation status and current changes in tested circuit, it help users fast and effectively locate the point with grounding fault.  
 
Technical Specification
- Operation environment
。Temperature: **0℃~**0℃
。Humility: ≤*5%
- Wireless communication
。Signal power: ≤ *0dbm
。Signal frequency: **3Mhz
。Sensitivity: ***6dBm
- Signal analyzer specification
。For DC system of *8V, **0V, **0V or customized voltage level.
。Voltage range of system to ground: ****0V
。Measurement of DC voltage to ground: ****0V
。Measurement of AC voltage to ground: ****0V
。AC interruption warning: ≥5V
。Voltage resolution: 0.1V
。Measurement range of system to ground:  ****9.9KΩ
。Grounding resistance resolution: 0.1KΩ
。Display: LCD
。Current detection signal: **2mA adjustable
。Voltage detection signal: ***0V adjustable
。Signal frequency: 0.*6Hz and optionally no-signal mode
。Anti-interference from DC distributed capacitance: ***0uF
。Power supply: powered by tested circuit
。Weight and dimension: 0.**3kg, **0***7**5mm
- Signal detector specification
。Insulation resistance (in signal mode)
。In **0V system: 0 ***0KΩ
。In **0V system: 0 ***0KΩ
In *8V system: 0 **0KΩ
Resistance resolution: 0.1KΩ
。Insulation resistance (in no-signal mode)
In **0V system: 0 **0KΩ
In **0V system: 0 **5KΩ
In *8V system: 0 **0KΩ
Resistance resolution: 0.1KΩ
。Waveform display time: *2 seconds
。Current measurement range: ±**0mA                  
。Current resolution: 0.*1mA
。Display: LCD
。Direction indication: forward or reverse direction indicating in arrow
。Anti-interference from DC distributed capacitance: ***0uF
。Distance from analyzer during signal tracing: no limitation
。Clamp jaw size:  *0mm
。Power supply: 5V by 4 pieces of AA standard battery
。Weight and dimension: 0.**2kg, **0***0**3mm
 
Kit includes:
。K****7 Signal Analyzer
。K****7 Signal Detector
。Qty. (1) Signal Testing Leads with clips
。Qty. (1) Current clamp with cable
。Qty. (4) Batteries
。Battery Charger
。Carrying Case
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

País: China
N º de Modelo: K-3837 Ground Fault Locator
Precio FOB: Obtener el precio más reciente
Lugar de origen: -
Precio de pedido mínimo: -
Cantidad de pedido mínimo: -
Detalle de embalaje: -
El tiempo de entrega: -
Capacidad de suministro: -
Tipo de pago: -
Grupo de productos : -

Send a direct inquiry to this supplier

A:

Diana < Kongter Test & Measurement Co. Ltd >

quiero saber: