Precio FOB
Obtener el precio más reciente120 ~ 450 USD / Liter ( Negotiable )
|1 Liter Minimum Order
País:
China
N º de Modelo:
AMS-99V
Precio FOB:
120 ~ 450 USD / Liter ( Negotiable )Obtener el precio más reciente
Lugar de origen:
Shanghai
Precio de pedido mínimo:
120 per Liter
Cantidad de pedido mínimo:
1 Liter
Detalle de embalaje:
barrel
El tiempo de entrega:
5-7days
Capacidad de suministro:
100000 Liter per Year
Tipo de pago:
T/T
Grupo de productos :
-
Persona de contacto Mr. Clement
Xinjunhuan road, Shanghai, Shanghai
The coating is used on building glass. By blocking the infrared
radiation from the sun, it can achieve the effect of heat
insulation, shielding ultraviolet rays, and energy saving, reduce
the energy consumption of air conditioning, and improve the comfort
of life.
Parameter:
Feature:
-Easy application, applied at will and freely, excellent leveling ability;
-High transparency, not affect visibility and lighting requirements, significant heat insulation and energy-saving;
-Strong weather resistance, after QUV 5000 hours testing, no change in coating, up 10 years service life;
-High surface hardness, good wear resistance, adhesion to grade
0.
Application:
Used for heat
insulation and energy-saving of building glass, such as business
buildings, hotels, high-end restaurants, zenith glass,
residential, etc.
Used for
industrial glass with requirements of infrared and ultraviolet
rays shielding.
Usage:
Please read the
following application process, methods and precautions, and watch
application video before use. Application ambient temperature
15~40℃, humidity below 80%. No
dust and other unfavorable factors.
(â… ) Application
Process
(â…¡)
Application Method
Step 1:
Prepare tools and materials as follows:
-Purified water:
used for the preliminary cleaning of the glass surface and the
purpose of using purified water is to reduce new impurities in
the process of cleaning the glass.
-Cleaning agent:
cleaning glass with special cleaning agent that has strong
decontamination ability, acting as the first glass
cleaning.
-Anhydrous
ethanol: 90% industrial alcohol is required to clean the glass
for the second time to remove the residual cleaning agent on the
surface of the glass.
-Plastic strip
and protective film: the glass frame is protected by plastic
strip during construction to ensure that the contact area between
the film surface and the glass frame is orderly. The protective
film is attached to the bottom edge of the glass frame to avoid
contamination of the wall and the ground during the coating
process.
-Coating and
diluent: solvent-based coatings can be divided into main
materials and diluents, and the corresponding amount of diluent
should be added according to the temperature of the same day in
order to get better brush. When the temperature is higher than
30 ℃, diluent(5% of the weight
of the main material) should be added, be sure to add the diluent
into the main material and mix evenly before
application.
-Measuring cup
and dropper, feed plate: used for weighing diluents, and using a
small amount of dropper to achieve accurate components, and
finally pour into the tray.
-Non-woven paper
and towels, sponge wipe: sponge wipe dipped in the appropriate
amount of cleaning agent, in a spiral way to wipe the surface of
glass, with a towel to wipe the remaining cleaning agent,
non-woven paper is used to clean the glass surface during the
second anhydrous ethanol cleaning, and wipe the tray and
measuring cup with the non-woven paper at the same time each time
the material is taken.
-Scraper tool:
clip the nano sponge strip onto the scraper tool, then dip it
into the coating and brush it.
Note: anhydrous
ethanol and pure water need to be provided by customers because
of inconvenient transportation.
Step 2: Clean
the glass. The glass is cleaned twice with special cleaning agent
and absolute ethyl alcohol.
The cleaning
agent is first extruded onto the sponge, and a small amount of
purified water is sprayed on the sponge, and then the sponge is
wiped on the surface of the glass by the sponge dipped with the
cleaning agent until the surface of the glass has no oily stain,
and then the cleaning agent is removed by a clean towel; (Note:
When the towel is wiped, the corner should be highlighted,
because the corner is not easy to clean after the adhesive tape
is attached. The erase cleaning agent can be used with a same
towel, but it is not possible to use a towel that is contaminated
with coating and dust). Clean the glass with anhydrous ethanol
for a second time; Spray the glass with appropriate amounts of
anhydrous ethanol, then wipe the glass with non-woven paper until
there is no visible dust. Anhydrous ethanol can no longer touch
the glass after it is wiped clean.
(Note: the
corner is the most prone to residual dirt, focus on cleaning and
wiping)
Step 3: border
protection.
In order to
avoid inadvertently touching the glass frame during the coating
process, and to keep the edges of the coated glass neatly, it is
necessary to use the plastic bar to cover the glass in accordance
with the regulations, to ensure that the cover is intact before
entering the next procedure. It is important to make sure that
the joint of coating and plastic strip is neat and orderly, and
that there must be one side glued to the glass when pasted,
especially at the corner, so as to ensure that a line is neat and
beautiful.
Step 4: Formal
coating (make sure the dry glass begins to be coated after
cleaning).
-Coating
weighing and preparation:
Clean the tray
and the measuring cup with absolute ethyl alcohol and non-woven
paper.
Pour the
corresponding amount coating into the measuring cup according to
the standard of 20 g/ m2. When the air temperature is higher than
30℃, the diluent with the weight of 5% of the weight of the
main material is required to be added into the main material and
mixed. The mixing method comprises the following steps: adding
the diluent into the measuring up according to a proportion, and
then pouring the diluent into another measuring cup filled with a
coating then shaking well.
Coating dosage
formula: glass height(m) × width(m) × 20g/m2
(Note: clean the
tray and measuring cup with anhydrous ethanol and non-woven paper
before and after each use.)
-Formal coating.
According to the construction glass area according to
20g/m2, weighing the required
coating, and pour all into the feed plate; Then use a nano sponge
absorbed the appropriate amount of coating, and scrape on glass
surface evenly from right to left, then from the bottom up to
ensure that the coating is evenly coated on the whole piece of
glass. Finally, starting from one side, the film is finished from
the bottom up to make sure that the film is free of bubbles, no
flow marks and uniform on the surface of the glass.
(Note: The
process of coating should be uniform speed, uniform strength and
do not push too much; from different angles to observe more,
whether there is an uneven phenomenon; After finishing, if the
defect is found, the scraper tool should be used in the shortest
time to swivel a few times in the defective place, then scrape it
up and down twice quickly, and then re-finish it. A small number
of crystal points may be observed on the surface after the
coating is completed, but no need to worry that, as the crystal
points will disappear within 24 hours.)
Step 5: Normal
temperature curing
After 20~60
minutes (it depends on the ambient temperature), the coating
surface is basically solidified. Within an hour of curing time,
no object can touch the coating; Within a week, no sharp thing
can touch the coating.
Step 6:
Checking
After the
surface of the coating is dried and solidified, remove the
material such as the paper adhesive tape, the protective film,
etc carefully.
Step 7: Record
and fill in the form
Record ambient
temperature, humidity, surface temperature and so on, do the
finishing work well.
(â…¢) Precaution
-In the process
of coating use, each take-off action should be rapid, as far as
possible to reduce the contact time between the coating and
air;
-Ambient
temperature shall be between 15 and 40℃, and the humidity shall not
be higher than 80% and there should be no water drops on the
surface of the glass;
-Open flame or
spark is not allowed nearby, and smoking is
prohibited;
-Stored in a
cool, well-ventilated place, avoid sun exposure, not close to
heat, fires, power sources;
- Keep out of
reach of children, and avoid contact with skin or
eyes;
- In case of
contact with eyes, flush with copious amount of water, call a
physician.
-Not fall onto
other surfaces to avoid corrosion, if contact, wipe with
anhydrous ethanol as soon as possible.
*Disclaimer
The sellers,
users, transportation and depositors (collectively referred to as
users) of the product need to obtain an effective, the latest
version of the chemical safety technology specification (MSDS)
from the official channels of Shanghai Huzheng Nanotechnology
Co., Ltd. and please read it carefully. It is suggested that
users should receive professional training.
País: | China |
N º de Modelo: | AMS-99V |
Precio FOB: | 120 ~ 450 / Liter ( Negotiable ) Obtener el precio más reciente |
Lugar de origen: | Shanghai |
Precio de pedido mínimo: | 120 per Liter |
Cantidad de pedido mínimo: | 1 Liter |
Detalle de embalaje: | barrel |
El tiempo de entrega: | 5-7days |
Capacidad de suministro: | 100000 Liter per Year |
Tipo de pago: | T/T |
Grupo de productos : | - |