Descripción del producto
I
Input
1? voltage?**0Vac?**8Vac
2?rated voltage?**0Vac
3? over-current protect?fuse?*5A?
4?power factor??0.*9
5?harmonic component??*0%
6? frequency?*0Hz/*0Hz
7? power(3 switch) : full power: ***0W±5% ; 3/4
power:**0W?**0W; 1/2 power:**0W?**0W
II
Output
1?rated output power??**0W?**0Vac?
2?lighting voltage?**0Vac?**0Vac
3?output frequency??*0KHz
4?current crest factor ??1.7
5?open-circuit voltage??**0V
6?firing voltage??4.5KV
7?overall efficiency??*0%(**0Vac)
III
Protect
1?short circuit protect? yes
2?open-circuit protect?yes
3?firing fault protect?yes
4?heating protect?yes
5?lamp lose efficacy protect ?yes
V
System
1?Complete machine appearance:
2?weight?3kg
3?distance from ballast to lamp ??*5.*4m
4?working temperature range?**0??**5?
5?max. case temperature?(Tc)*0?
6?size?**1***2**2mm
VI
Notice?
1?Not read and understand this statement before, do not operate the
electronic ballast
2?The electronic ballast starting voltage may be up to ***0 volts,
may harm on human peripheral or equipment. Please pay attention to
the potential danger and during operation do not contact any
conductive object.
3?The electronic ballast starting voltage up to ***0 volts,
electronic ballast to the bulb attachment should be as short as
possible and have sufficient voltage withstand strength.
4?The electronic ballast can not be installed or used in the
environment of explosive / volatile gases, can not be started in
the adjacent of flammable gas and liquid.
5?Because without voltage insulation between the and the
output, so the output terminal is grounded or connected directly to
ground will damage electronic ballast.
6?The electronic ballast for shell type applications, in all
application requirements have forced the electrical safety and
radio frequency interference suppression.
7?
The electronic ballast of all installation and repair shall be
certified qualification engineer operation in removing the
enclosure in the repair process must always follow the local
safety standard operating.
Note: in accordance with the local safety standards, must be in
the use of electricity use of insurance;
Recommend class 2
insurance, the insurance of the general formula is:
Fuse rated current ≥ 1.*5 X lamp power / Min. AC
voltage
VII Application
Widely used in various types of grow
lamp, engineering lighting, bus station, airport, Pier lighting ,
Road, square lighting, building, landscape lighting, stadium
lighting, advertising lighting etc.
País: |
China |
N º de Modelo: |
XYW-HPS600W
|
Precio FOB: |
200 ~ 400 / Unit (Negociable)
Obtener el precio más reciente
|
Lugar de origen: |
- |
Precio de pedido mínimo: |
200 per Unit |
Cantidad de pedido mínimo: |
10 Unit |
Detalle de embalaje: |
- |
El tiempo de entrega: |
- |
Capacidad de suministro: |
- |
Tipo de pago: |
T/T |
Grupo de productos : |
- |