LASWIM MULTIFUNCTION DEHUMIDIFIER OPERATING PRINCIPLE
LASWIM
multifunction dehumidifier is specially developed for the indoor
swimming pool, such as large indoor athletic pools, competition
pools, commercial pools and hotel pools, etc. Combining multiple
functions of dehumidification, pool water heating, pool room
cooling and heating , heat recovery and indoor air handing in one
unit by intelligent integration control, it is also called air
handing unit.(AHU)
The system recycles the heat captured during dehumidification to
heat the air or water while the air system effectively absorbs heat
from the exhaust air stream, perfectly solve the problem of high
humidity and high chlorine diffusing in the pool room. It is
energy-efficient by conversing the operating modes according to the
seasonal changes, and reduce the pool operating cost while
providing a optimum space and water conditions.
When the recycled heat is insufficient to meet the room temperature
requirements in cold winter, the auxiliary heating coil can help to
eat the indoor room air. As long as the dehumidification system is
provided with the necessary operating electric power, it will
operate in a continuous cycle and compensate the heat lost of the
pool water. In this way to balance the functions of humidity
control, water/air temperature control and real time fresh air
requirements.
DETAILS OF HIGH
QUALITY COMPONENTS
1. High quality
compressor
International
famous brand, with precise energy stage settings, ensure the
working unit to achieve the desirable energy saving effect, high
efficiency, durable and quiet operation.
2.ECO-friendly
refrigerant
ECO-friendly
refrigerant R410A or R407C, no emission of pollutants, no
greenhouse effect and no ozone layer destruction.
3.Intelligent touch
control system with real color display
Adopts
precise and intelligent control system with high protection level
(IP65) touch screen. Various control options are prepared, can
contact signal or Modbus RS485 protocols for easy operation and
convenient management.
4.Detachable
modular integrated design and superior
casing
The
panel is made of GI steel and special anti-corrosion treatment
(epoxy coating) is conducted. The middle layer of the panel is PU
foam with light weight, good rigidity, and thermal conductivity.
The base is made of channel steel, and the frame is made of
aluminum alloy which cold bridge effect is avoided. Adopts
detachable modular design, which is more fashionable and robust to
suit different site conditions.
5.Titanium in PVC
heat exchanger
With
excellent corrosion resistance and good heat exchange
effect.
6.Hydrophilic film
aluminum foil evaporator
The
corrugated fin type heat exchanger with superior performance
greatly increases the heat exchange area and improves the heat
exchange effect. The fin is treated with hydrophilic corrosion
resistant film, for strong corrosion resistance and long service
life.
7.Outdoor
condenser
The
standard outdoor condenser is air cooled condenser, water cooled
condenser is available according to the project
requirement.
8.Removable and
washable air filter
The
system is equipped with removable and washable air filter, which is
non-toxic, non-allergic and anti-bacteria. The aluminum alloy mesh
is staggered and overlaid, to effectively filter the air entering
the evaporator, with the features of non-rust, non-corrosion, high
precision. high efficiency and easy to
clean.
PRODUCT
FEATURES:
1.Extremely high
efficiency and energy saving
Recovers 80% of the
latent heat from the hot and humid air, and saves an average cost
of 40-60% compared with the traditional dehumidification
system.
2.One machine with
multiple functions for new user experience, and meets different
needs of the four seasons.
Covers
five functions of dehumidification, pool water heating, pool room
cooling and heating, heat recovery and indoor air handing, to
create a high-quality and comfortable air
environment.
3.Electricity and
water are separated, safe and reliable.
Separation of water
and electricity, no electric shock, flammable, explosive, poisoning
and other safety hazards.
4. Dry and wet
partition layout to prevent chlorine
corrosion.
The
refrigerant system and the air duct system are independent and
separate, to prevent the corrosion of the heat pump by
chlorine-containing air.
5.Safe and reliable
performance
Equipped with high
quality and famous brand scroll compressor, thermal expansion valve
and other critical electronic components, to ensure a stable and
high efficient operation.
6.New air treatment
technology : using plasma sterilization and AOT to remove
DBPS(optional)
Advanced
photocatalytic oxidation(AOT) technology is used to remove
disinfection by-products(DBPs) such as ammonia nitrogen and other
volatile organic compounds(VOCs) from indoor air, to eliminate air
pollution and inducement of asthma in natatorium.
7.Multiple system
protection
With
multiple protection such as the following to ensure safe operation
and long service life.
*High
pressure protection and low pressure protection;
*No
water flow or insufficient water flow protection;
*Temperature
protection: excessive exhaust temperature protection, compressor
high temperature protection, hot water overheat
protection;
*Power
protection: phase missing or error protection, compressor overload
protection.
Model | LAS20-D | LAS30-D | LAS40-D | LAS50-D | LAS60-D | LAS80-D | LAS100-D | LAS125-D | LAS140-D | LAS160-D | LAS180-D | LAS200-D | LAS230-D | LAS260-D | LAS300-D | LAS400-D | |
Dehumidification capacity (kg/h) | 19 | 31 | 40 | 50 | 61 | 81 | 102 | 126 | 133 | 163 | 182 | 202 | 232 | 262 | 303 | 402 | |
Total heat capacity (kW) | 32 | 55 | 73 | 89 | 106 | 145 | 188 | 267 | 317 | 335 | 399 | 426 | 479 | 526 | 574 | 765 | |
Evaporator cooling capacity (kW) | 27 | 47 | 62 | 75 | 90 | 123 | 159 | 227 | 269 | 284 | 338 | 361 | 406 | 446 | 487 | 650 | |
Standard Air flow (m³/h) | 4500 | 9000 | 10500 | 12000 | 14800 | 18000 | 23000 | 29000 | 31000 | 34000 | 39000 | 42000 | 48000 | 54000 | 62000 | 66000 | |
External residual pressure (Pa) | 300 | 350 | 350 | 350 | 350 | 400 | 400 | 450 | 450 | 450 | 450 | 500 | 500 | 500 | 600 | 600 | |
Power supply (V/N/Hz) | 380V/3N/50Hz |