Description
Description
Morningtest Temperature Chambers with Stainless Steel Inner
Material focus on the required temperature simulation only in order
to successfully carry out complex cooling/heating tests between **0
°C and **0 °C. Chambers with Single-stage Refrigeration
systems are capable of achieving workspace temperatures down to
**0°C. This is fine for many commercial and industrial tests that
require low temperatures of typically 0°C, **0°C or **0°C. A
single-stage system uses one compressor to directly cool the
workspace.
Chambers with Cascade Refrigeration systems are capable of
achieving workspace temperatures down to **0°C~**0°C depending on
model. This is required for many ruggedized industrial, automotive
and military test procedures that require low temperatures of
typically **0°C, **5°C or **5°C. A cascade system uses two
interdependent compressors.
Note:
Chamber size could customize
If test specimens have active load during test, please informed
us.
This is temperature only model, if need make humidity test, please
refer to humidity chambers.
Model &Working room Size
MT***1T (W*D*H) **0***0* **0 mm
MT***5T (W*D*H) **0***0***0mm
MT***4T (W*D*H) **0***0***0mm
MT***6T (W*H*D)***0***0****0mm
MT****0T (W*H*D)***0***0****0mm
Performance
· Control model: Balanced Temperature &
Humidity Control System (BTHC system)"
· Temperature range(Optional):A: 0~**0℃
B:**0~**0℃ C:**0~**0℃ D:**0~**0℃ E:**0~**0℃
· Temperature fluctuation: less than or equal
to plus or minus 0.5 degree
· Temperature uniformity: less than or equal
to 2 degree
· Temperature deviation: less than or equal to
plus or minus 2 degree
· Heating rate: 1~3 degree per min
· Cooling rate: 0.7~1 degree per min
Standard Features:
Cabinet
· Interior stainless steel plate (sus#**4)
· Baked panel and durable blue powder coated
exterior steel plate
· High density polyurethane froth insulation
or fiberglass insulation
· Welded structural base frame with removable
service panels
· Dual silicone one-piece door gaskets with
vulcanized corners
· Multilayer tempered heated viewing window;
Anti-condensation & frost free
· One leak-proof *0mm (2 ") access port with
plug on the left
· 4 heavy duty casters
· Fin heat disperse-stainless steel heater
· PID controlled-stainless steel
humidifier
· 2 levels shelves, stainless steel
· Temperature measuring with PT**0 in air
outlet
· Chamber drain
Electrical
· Anti-explosive interior lamps
· AC Power Cord
· Fast recovery fuses
· High pressure protect
· Phase reversal protect
· Circuit breaker system
· System fault status indicators
· All wiring color coded and labeled for
troubleshooting
· High temperature failsafe limit
Refrigeration
· Dupont R***4A [No Fluorine] Refrigerant
· Hermetic-single/cascade compressor
· Air cooled type (Fins with fan)
condenser
· Oil separator
· High efficiency plate heat exchanger
· Inherent compressor overload protection
Controls
· Japanese Unique 7" color touch-screen
controller
· Self prompting operation with **0
programmable segments.
· **0 days historical date
· Real-time and historical curve record
· Ethernet Connection
· USB-Connection to save measuring data on USB
Stick
· Online software to connect the PC with the
controller to operate from PC
Calibration
· Calibration report for temperature humidity
values from manufacturer
Optional Accessories:
· Additional cable access ports *0 mm, **0 mm
and **0 mm
· Additional shelves
· Glove ports to move the test specimen
without opening the door
· Chart recorders
· Microprocessor (digital indicator)
controller
· **0, **5,**0 or **0 Volts power input
optional (depend on requirement)
· Dry air or nitrogen purge. (Low humidity
requirement)
· Boost cooling system, LN2 or CO2 (enable
faster cooling rate and product temperature change rates in an
environmental chamber)
· Additional Pt **0 for temperature measuring
on test specimen
· Additional temperature protection for test
specimen
· Smartphone or tablet pc WIFI monitoring
· Heat only models available
· Variable air speed in the test space
· Water cooled condensers with coil pipe
available
· Calibration certificate for temperature
humidity values from 3rd measurement institution.
· RS***2/RS***5 data interface
Please contact Morningtest by sissi(at)morningtest(dot)com for more
information and quote.