FOB Price
Obtener el precio más reciente( Negotiable )
|Minimum Order
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
1 Piece
Packaging Detail:
carton
Delivery Time:
20days
Supplying Ability:
500 Piece per Month
Payment Type:
T/T, Western Union
Persona de contacto john
1605, Building 12, Dingtai Fenghua Phase 6, Qianhai Road, Shenzhen, Guangdong
Peak current(A) | RMS current (A) | SW1 | SW2 | SW3 |
1.0 | 0.7 | OFF | OFF | OFF |
1.4 | 1.0 | ON | OFF | OFF |
1.9 | 1.4 | OFF | ON | OFF |
2.4 | 1.7 | ON | ON | OFF |
2.8 | 2.0 | OFF | OFF | ON |
3.2 | 2.3 | ON | OFF | ON |
3.8 | 2.7 | OFF | ON | ON |
4.2 | 3.0 | ON | ON | ON |
Pul/rev | SW5 | SW6 | SW7 | SW8 |
200 | ON | ON | ON | ON |
400 | OFF | ON | ON | ON |
800 | ON | OFF | ON | ON |
1600 | OFF | OFF | ON | ON |
3200 | ON | ON | OFF | ON |
6400 | OFF | ON | OFF | ON |
12800 | ON | OFF | OFF | ON |
25600 | OFF | OFF | OFF | ON |
1000 | ON | ON | ON | OFF |
2000 | OFF | ON | ON | OFF |
4000 | ON | OFF | ON | OFF |
5000 | OFF | OFF | ON | OFF |
8000 | ON | ON | OFF | OFF |
10000 | OFF | ON | OFF | OFF |
20000 | ON | OFF | OFF | OFF |
25000 | OFF | OFF | OFF | OFF |
Name | function | description |
PWR | Power light | When power on ,the green light is on |
ALARM | Over current/under voltage/over voltage displaying light | If the drive Over current/under voltage/over voltage, the red light is on |
PU+ | Pulse input positive |
Pulse signal: In single pulse
(pulse/direction) mode, this input represents pulse signal, each
falling edge active; 4-5V for High -level, 0-0.5V for
low-level Series connect resistors for current-limiting when +12V or +24V used.(should connect 1k resistor for +12V,2k for +24V) |
PU- | Pulse input negative | Pulse signal: In single pulse (pulse/direction) mode, this input represents pulse signal, each falling edge active; 4-5V for High -level, 0-0.5V for low-level |
DR+ | Direction input positive |
DIR signal: In single-pulse
mode, this signal has low/high voltage levels, representing two
directions of motor rotation; Series connect resistors for current-limiting when +12V or +24V used.(should connect 1k resistor for +12V,2k for +24V) |
DR- | Direction input negative | DIR signal: In single-pulse mode, this signal has low/high voltage levels, representing two directions of motor rotation; |
MF+ | Enable input positive |
Enable signal: This signal is
used for enabling/disabling driver. High level for enabling the
driver and low level for disabling the driver. Usually
leftUNCONNECTED
(ENABLED). Series connect resistors for current-limiting when +12V or +24V used.(should connect 1k resistor for +12V,2k for +24V) |
MF- | Enable input negative | Enable signal: This signal is used for enabling/disabling driver. High level for enabling the driver and low level for disabling the driver. Usually leftUNCONNECTED (ENABLED). |
V- | Power input COM | DC20-50V |
V+ | Power input VCC | |
A+,A- | Motor A phase | Connect to Motor A phase |
B+,B- | Motor B phase | Connect to Motor B phase |