FOB Price
Obtener el precio más reciente350 ~ 450 / Piece ( Negotiable )
|Minimum Order
Place of Origin:
-
Price for Minimum Order:
Minimum Order Quantity:
1 Piece
Packaging Detail:
Cartons
Delivery Time:
by express, by air, by ship
Supplying Ability:
20 Piece per Week
Payment Type:
T/T, Western Union, Money Gram
Persona de contacto Ms. Maggie
No.2 Huangcun RD,Tianhe DIstrict,, Guangzhou, Guangdong
~Multiple valve controller_ JMA stager controller_Multi-valve
system controller
Multiple valve controller Introduction
Multiple valve controller functions:
â—† Password setting
â—† Calendar
â—† Regeneration stage and regeneration time indication
â—† JMA can be initiated manually or through remote control. Timer
initiation and interval initiation are also
Multiple valve controller available.
â—† Manual step by step initiation (only for system
commissioning)
â—† Reset function
â—† Stages (**8) and stage duration (*****9 Sec) settings
â—† System working stage indication (Service or regeneration stage
indication)
â—† Data protection after power cut: settings and data can be
stored for 3 years.
â—† Waterproof and rotproof enclosure
JMA stager controllerMultiple valve controller working
principle:
The stager may be manually operated or driven by an electric motor
that operated through an adjustable timer or flowmeter program. The
stager functions by opening and closing its ports, singly or in
combination, in a sequence that fit the need of the system. The
positions in the sequence correspond to the number of stager in the
process (See chart 1). The port that are opened allow the
pressurized fluid to flow to and operate some diaphragm valves,
while venting other valves—allowing them to return to their
normal positions.
The stagers can use either hydraulic or pneumatic control fluid.
Continuous electrical power is not required to maintain the
positions of the valves such as in a solenoid operated system.
Greatly avoid the system breakdown because of power failure.
All types of complex application can be controlled by stager
controller system through correct design and combination of the
stagers.
Â
~JMA stager controller specifications:
â—† Automatic restoration function
â—† Waterproof enclosure (waterproof and shockproof)
â—† Power supply: **0VAC/*0HZ
â—† Timer initiation setting: any time of the day 7 days one
week
â—† 8 stages available with duration from 5 to ***9 seconds for
each stage
â—† Manually initiation
â—† Service/regeneration Light indication
â—† Auxiliary signal output
Multiple valve controller Technical figures:
Electrical supply: **0VAC/*0HZ, *0W
Remote control signal: At least 2 seconds/dry contactor
Pressure port size: 1/8G thread
Control fluid: hydraulic or pneumatic (**0μfilter is recommended
for the system)
Control fluid pressure: 0.2~0.8MPa
Temperature: 4~*0℃
Enclosure size: **0 mm X **0 mm X **5 mm
Multiple valve controller Applications:
Item ID Typical application
 Stage program
Â
JMA **1
 Filter
 Service→backwash→rinse
Â
JMA **2
 Co-current regeneration softener
 Service→backwash→brine + slow wash→rinse
Â
JMA **3
 Filter
 service→backwash
Â
JMA **5
 Counter-current regeneration softener
 Service→backwash→brine + slow wash→rinse
Â
JMA **6
 3 tanks filter
 service→1#backwash→2#backwash→3#backwash
Â
JMA **7
 4 tanks filter
 service→1#backwash→→→4#backwash
Â
JMA **8
 5 tanks filter
 service→1#backwash→→→→5#backwash
Â
JMA **3
 2 tanks filter (1service 1 stand by )
 1#service→1#backwsh→2#service→2#backwash
Â
JMA **4
 Co-current regeneration water softener
 service→backwash→brine→slow wash→rinse→refill
Â
JMA **5
 Co-current regeneration water softener
 service→backwash→brine→slow wash→rinse
Â
JMA **6
 Co-current regeneration water softener
 service→backwash→brine→rinse→refill
Â
JMA **7
 2 tanks parallel filter
 service→backwash 1→rinse 1→backwash 2→rinse 2
Â
JMA **8
 Filter
 service→drain→air flush→backwash→rinse
Â
JMA **9
 Brine recycle water softener
 service→backwash→brine→brine+slow wash→brine recycle
→rinse
Â
JMA **0
 6 tanks filter
 service→1#backwash→→→→6#backwash
Â
JMA **1
 7tanks filter
 service→1#backwash→→→→7#backwash
Â
Â