FOB Price
Obtener el precio más reciente300 ~ 600 / Set ( Negotiable )
|Minimum Order
Place of Origin:
-
Price for Minimum Order:
Minimum Order Quantity:
1 Set
Packaging Detail:
carton
Delivery Time:
3-5 days
Supplying Ability:
200 Set per Day
Payment Type:
Western Union, T/T
Persona de contacto Mr. Stephen
guangzhou, Guangzhou, Guangdong
Parameter of vortex flow meter | |||||
Measured Mediums | liquids, gases and steams (NOTE: the mediums should be unidirectional or can be seen as unidirectional.) | ||||
When the dryness of saturated steams ≥*5%, they can be seen as unidirectional. | |||||
Temperature of Mediums | - *0°C ~ + **0°C | ||||
Pressure of Mediums | 1.6MPa, 2.5MPa, 4.0 MPa | ||||
For over 4.0 MPa, please contact us freely, for it needs special customization. | |||||
Accuracy | 1.0;Â 1.5 | ||||
Span Rate | 1:8 ~ 1:*0(compared with the standard atmospheric pressure) | ||||
1:8 ~ 1:*0 ( compared with the nominal temperature water) | |||||
Flow Range | Liquids: 0.4 ~ 7.0 m/s | ||||
Gases:Â 4.0Â ~Â *0.0Â m/s | |||||
Steams:Â 5.0Â ~Â *0.0Â m/s | |||||
Nominal Diameter | DN *5, *0, *0, *5, *0, **0, **5, **0, **0, **0,**0 mm | ||||
Materials | 1Cr*8Ni9Ti | ||||
Reynolds No. | Normally, 2***4 ~ 7***6 | ||||
Resistance Coefficient | Cd ≤ 2.6 | ||||
Licensed Vibration Acceleration | LUGB type ≤ 0.2g | ||||
Class of Protection | IP*5 | ||||
Class of Explosion-Proof | Intrinsically Safe Explosion-Proof: Exia II CT2 ~ CT6 | ||||
Explosion Suppression: Exid II CT4 | |||||
Conditions of Surroundings | Temperature of Surroundings: | Non-Explosion Proof Surroundings: **0°C~ **5°C | |||
Explosion-Proof Surroundings: **0°C~ **5°C | |||||
Relative Humidity: | ≤ *5% | ||||
Atmospheric Pressure: | *6 ~ **6 kPa | ||||
Power Supply | Non-Explosion Proof Type | Pulse type: | **2 VDC ( the output current is 4 ~ *0mA) | ||
Current type: | **4 VDC ( the output current is 4~ *0mA) | ||||
Explosion-Proof Type | Current type: | **4 VDC ( the output current is 4~*0mA) | |||
Output Signal | Frequency pulse signal 2~***0Hz, low level voltage ≤1V, high level voltage ≥ 6V | ||||
Two-wire system 4 ~ *0mA signal (isolation output), load ≤ **0Ω. |
Â
Measuring range of vortex flow meter MT**0VX
Measure range of vortex flow meter | ||
Diameter (mm) | Water | Gases in the Normal Temperature and Pressure |
Range of Standard Measurement (m3/h) | Range of Standard Measurement (m3/h) | |
 *5 |  2 ~ *6 |  8~*0 |
 *2 |  1.5~*5 |  *4~**0 |
 *0 |  3~*0 |  *8~**0 |
 *0 |  4~*0 |  *0~**0 |
 *5 |  6~*0 |  *0~**0 |
 *0 |  *3~**0 |  *0~**0 |
 **0 |  *0~**0 |  **0~***0 |
 **5 |  *6~**0 |  **0~***0 |
 **0 |  *0~**0 |  **0~***0 |
 **0 |  **0~***0 |  **0~***0 |
 **0 |  **0~***0 |  **0~***0 |
 **0 |  **0~***0 |  ***0~****0 |
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â