hv vacuum circuit breakerfor mine GVS7-12

hv vacuum circuit breakerfor mine GVS7-12

1 ~ 2000 / Set ( Negotiable )

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

1 Set

Packaging Detail:

wooden case

Delivery Time:

within 10 days after receive deposit

Supplying Ability:

1000 Set per Month

Payment Type:

T/T, L/C, Western Union, Money Gram

Contactar ahora
Miembro Básico

Persona de contacto Ms. crystal

No.111 , Xinguang Road, Xinguang Industrial Zone, Liushi, Wenzhou, Zhejiang

Contactar ahora

Description

GVS***2 Series High Voltage Vacuum Circuit Breaker for Mine

GVS***2 series high voltage vacuum circuit breaker for mine, adapt to our company own developed overall type spring operating mechanism, combined with flameproof electrical feeds, development, production of miniature circuit breaker. Use for underground three-phase AC *0Hz, rated voltage *2 (7.2) kV of mine explosion-proof device, available for coal mine explosion-proof electrical feeds, and general occasions of mine electrical control and protection purpose. Circuit breakers can be installed as handcart-type or fixed structure to meet the needs of different installation sites.

 

The Use of Environmental Conditions

  1. Altitude: not exceed ***0m.
  2. Ambient Temperature: not higher than **0°C, not less than **5°C.
  3. Relative Humidity: daily average of not more than *5%, month average of not more than *0%.
  4. Earthquake Intensity: not more than 8.
  5. The ambient air without water drop, no serious filthy, chemical corrosion as well as place of intense vibration.

 

Mainly Technical Parameters

NO.

Item

Units

Value

1

Rated voltage

kV

*2(7.2)*

2

Rated frequency

Hz

*0

3

Rated lightning impulse voltage tolerance (peak)

kV

*2(*2)*

4

Rated short-time power-frequency voltage tolerance (1min)

kV

*5(*0)*

5

Rated current

A

**5,**0,**0,**0

6

Rated short-circuit breaking current

kA

2.5,*6,*0,*5

7

Rated short-circuit closing current (peak)

kA

*1.5,*0,*0,*3

8

Rated short-circuit duration time

S

4

9

Rated operating sequence

 

O*0.3s-CO***0s-CO

*0

Rated short-circuit breaking current breaking number

Times

*0

*1

Closing time

ms

*5~*0

*2

Opening time

ms

*0~*0

*3

Mechanical life

Times

****0

*4

Rated storage and operation voltage

V

AC**0/**0DC**0/**0

*5

Contact distance

mm

*0±1

*6

Contact over travel

mm

3.5±1

*7

Average closing speed

m/s

0.7~1.0

*8

Average opening speed

m/s

1.1~1.5

*9

Contact closing spring time

ms

≤2

*0

Three phase closing opening asynchrony

ms

≤2