¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Automatic Wall Mounted Faucet 8178

Sell Automatic Wall Mounted Faucet 8178

48 ~ 55 / Piece

|

Minimum Order

Place of Origin:

China

Price for Minimum Order:

Minimum Order Quantity:

200 Piece

Packaging Detail:

-

Delivery Time:

7-30days or negotiable

Supplying Ability:

10000 Piece per Day

Payment Type:

T/T, L/C

Contactar ahora
Miembro Básico

Persona de contacto Ms. emma

1st building ailiu industrial zone ,baining99, ningbo, zhejiang

Contactar ahora

Description

Features:

1. Control :Designed with SCM. Stop water automatically when water flowing exceed 1 minute.
2. Adjustable Distance:Induce distance can be adjusted free of touching
3. Strainer Device: Strainer can be removed and clean to prevent blocking.
4. Anti-blocking Needle: The solenoid valve is protected by anti-blocking needle inside.
5. Structure:Swivel faucet spout for a convenient using.

Technical datas:

   Model           DC                     AC                     AD
    Power Supply   DC:6V   

   AC:**0V.**0V***0V

       *0Hz**0Hz

     AC:**0V***0V.*0Hz**0Hz

         DC:6V(Auto Swith)

    Faucet Body Material                                                      Brass
    Applicable Water Pressure                                                     0.***0.7MPa
    Water Temperature                                                     0.***0ºC
    Environment  Temperature                                                     0.***5ºC
    Water Supplying Caliber                                                     G1/2.G3/8

Overall dimensions:
                         

Installation diagram:

 

Installation guide:

Please connect the supplied flexible hose to the water inlet connection on the control box.

Please follow the instructions in drawing 1 if only cold water is used.

In case of using both hot and cold water supply, please install a  mixing valve prior to connection to the control box in accordance with drawing above.

Install the control box on the wall in accordance with appropriate EU regulations for safety and/or applicable local standards.

Install the faucet on the wash hand basin, please review drawing 2 for reference.

Connect the flexible hose to the water outlet connection on the control box.

Connect the sensor cable to the control box.

Make sure all water connections are tested and found without leakage prior to switching on the power the control box.

Plug in the power cable and/or install 4 AA Alkaline batteries.

 

Instructions for use:

  1. Sensor/flow test.

When the unit is powered on, water should flow immediately when you put your hands within range of the sensor. When you remove your hands out range the water should stop immediately.

The maximum duration of continuous flow is 1 minute.

  1. Sensor range

The default factory set distance is *2~*5 cm. When powered on  for the first time, place your hands at the desired distance within 5 seconds after the power has been switched on and remove your hands after approx 2 seconds in order to change the factory setting.

To reset the setting, interrupt power for at least *0 seconds and follow the procedure as described to set the sensor range correctly.

  1. Strainer

To prevent blockage please clean the strainer regularly, make sure you shut of the water mains, unscrew the water inlet hose, remove the strainer, clean with water and a soft brush.  Then install the items in reverse order, turn on water mains and check for leakage.

 

 Battery Change:

The indicator light in the sensor will flicker 3 times per second to indicate the batteries are at the end of their useful life. At this stage the unit will not operate in battery more  anymore

In case you have plugged in the mains, disconnect power and open the  cover of the control box, open the battery holder, remove the batteries and replace all batteries with new ones.

Please make sure you install the batteries in the right direction, the + and – side are indicated in the battery holder.

Close the battery holder, place the cover back in place and tighten the screws.

Follow the instructions for setting the sensor range if required.

 

 Problem:

The unit does not work.  Please check for power connection or replace the batteries, check connection of the sensor cable.

There is power however no water flow,

Please check the water supply, open any closed valves if necessary

Check water connections for blockage, clean if necessary

Check Strainer for Blockage, clean if necessary

Disconnect power for *0 seconds and re install

Check water connections for twists

Check sensor cable connection

Clean the sensor with a soft cloth

 

Caution: