¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Box-Type Water-Cooled Chiller (Normal temperature type)

Box-Type Water-Cooled Chiller (Normal temperature type)

|

Minimum Order

Place of Origin:

Shanghai

Price for Minimum Order:

-

Minimum Order Quantity:

1 Unit

Packaging Detail:

Plywood Packaging

Delivery Time:

-

Supplying Ability:

-

Payment Type:

T/T, L/C

Contactar ahora
Miembro Básico

Persona de contacto Ms. lorita

Huiye road 398-98,Export Processing Zone of Songjiang District, Shanghai, Shanghai

Contactar ahora

Description

HBP box-type of industrial water chiller 1. Principle and Use: Box-type industrial chillers are use air or water for condenser cooling medium, use water as the refrigerant of the industrial cooling equipment. It Widely used in various fields of plastics, electronics, food, pharmaceutical, electroplating, chemical, printing, coating, laser and CD-ROMs and other industrial equipment or mold cooling 2. Type: Within the box-type industrial chillers containing chilled water pump and water tank, on-site installation is simple, easy to maintain; Box-type industrial chillers are air-cooled and water-cooled two for the selection of customers according to the situation. 3. Evaporator: 3 - 5HP chiller using a submerged coil evaporator unit 8HP more than a shell and tube or plate evaporator heat transfer efficiency, and water resistance. 4. Controller: All microcomputer controller accurate, intelligent, and truly achieve perfect control of the machine, thus ensuring the safe operation of the unit and achieve the purpose of effective energy-saving, easy to use, friendly interface. 5. Water temperature & Antifreeze solution: Box-type industrial chillers can achieve a variety of cold bottled water and add the appropriate antifreeze in the chilled water side, 0C to - *5C the water temperature, in order to adapt to different industrial cooling requirements. 6. Protection: Box-type industrial chillers have perfect protection function, such as power wrong phase lack protection, System high-voltage protection, System low voltage protection, Double antifreeze protection, Compressor overload protection, The insufficient frozen water cooling protection, Prevent frequent start protection, Compressor built-in exhaust temperature and coil overheat temperature protection and so on. 7. Receive customized: The company accept all kinds of special technical requirements of units to order, can be customized explosion-proof, strong acid, strong alkali solution, cryogenic, heterogeneous power supply, T3 conditions non-standard products. 8. Pump & Water tank: Containing stainless steel water pump and water tank inside the box chillers standard accessories; Pump is lift, flow, adapt to the strong; Large capacity water tank, can automatic replenishment, overflow, effectively buffer the load change, the introduction of water temperature fluctuations. 9. Microcomputer function: Many of the chiller with compression, microcomputer automatic memory will be per compressor operation time, start the next time it will be activated running less time compressor. *0. Environmental protection refrigerants: Air cooled low temperature condition (*0 C below) water chillers the Copeland of the low temperature and environmental protection compressor for R**4A refrigerants, higher efficiency, to live longer, environmental protection and energy saving. In order to better protect the atmosphere, it Can producte green environmental protection etc cooling medium refrigeration and air conditioning equipment not only in adopts HFC**7C and HFC**4A, but also in HCFC*2. *1. Movement: *- 8HP of the box-type industrial chiller`s bottom of the fuselage is equipped with a wheel, you can easily move. Notes: (room temperature) default conditions 1. The parameters in the nominal conditions are as follows: chilled water inlet / outlet water temperature is *2deg. C/ 7deg. C; Ambient temperature is *5deg. C. 2. Temperature conditions: Chilled water inlet temperature range 9deg. C~ *0 deg. C ambient operating temperature 0 deg. C ~ *3 deg. C 3. Host the actual head of the pump head, minus the host internal head loss ( 1mH2O = 9.8kPa ). 4. Nominal conditions evaporation device water side of the dirt coefficient is 0.**8 m • ° C / kW 5. Power standard: 3P- **0V - *0HZ, it is recommended that the three-phase system, allowing the voltage fluctuation of ± 5 %, the frequency fluctuations of ± 2%

Send a direct inquiry to this supplier

A:

Ms. lorita < Shanghai Henbusch Air Conditioning Equipment CO., LTD >

quiero saber: