¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell PEC-10 Three Phase Energy Meter on-site calibrator

Sell PEC-10 Three Phase Energy Meter on-site calibrator

( Negotiable )

|

Minimum Order

Place of Origin:

China

Price for Minimum Order:

-

Minimum Order Quantity:

2 Set

Packaging Detail:

aluminium alloy box

Delivery Time:

15-20 days

Supplying Ability:

-

Payment Type:

T/T, Western Union

Contactar ahora
Miembro Básico

Persona de contacto Ms. Sophie

Kehui Industrial Park, Jinyuan 1st Rd, Zhhai National High-tech zone, Zhuhai, Guangdong

Contactar ahora

Description

Main Features:
 

  1. Accuracy:0.*5 and 0.1 class
  2. Integrative tester with power, calibrate without any load; the maximum output current and power of each phase is *0A and 8VA respectively.
  3. Output in any power factor point
  4. Can calibrate online and off-line working energy meter error
  5. Check lines without any load, measure the comprehensive error and the wirings before metering cabinet working
  6. Fluctuating load error is stable, and can connect with the marketing system
  7. Clamp meter’s self-calibration function—Kehui Patent
 
 
Main function:
1、Error calibration
  ①、Can calibrate the error at one time for all kinds of mechanical and electronic energy meter, the main and sub-meters in a circuit, multifunction meter’s active/reactive as well as the comprehensive error of low-voltage metering device.
  ②、The error is stable in load fluctuation test condition.
2、Parameter measurement:
Can test various kinds of electrical parameters on site such as U, I, P, Q, Φ, F etc.
3、Harmonic measurement:
Can calibrate each phase voltage and current harmonic in *1 times on site, and take the fundamental wave as the full-scale.
4、Waveform display:
Can measure and real-time display waveforms of each phase voltage and current, convenient to analysis.
5、Check Line
  ①、No load check line, can check wirings before metering cabinet put into operation
  ②、More perfect wrong-wiring identification function, measure and real time display hexagon vector diagram.
6、Secondary load measuring
TA and TV secondary load test function
7、Ratio test 
Can measure TA ratio to analysis the fault and find the electricity-stealing phenomenon
8、Can ensure the accuracy in**0oC~*0oC and the humidity in *0%~*5%.
 
 
 