Technical Data:
System Specifications
Adopt ballistic method measurement, technical indices as follows:
Parameters measured | Bs (%) | Br (%) | Hc (%) | Pu (%) | μ m (%) | μ i (%) |
Uncertainty (k = 2) | 1 | 1 | 1.5 | 1 | 2 | 5 |
Repeatability (constant temperature) | ± 0.5 | ± 0.5 | ± 0.5 | ± 0.5 | ± 1 | ± 3 |
When testing hysteresis loop with scanning method, H and B measuring errors can be estimated as: B: 1% + 1/2 LSB H: 1% + 1/2 LSB
Instrument Specifications
MATS - ***0SD Static Hysteresisgraph | PC***6 A/D D/A Card | |
Output Voltage: 0 ~ ±*5 V Output Current: 0.*1 mA ~ *0 A Current Range: 1 mA, 2 mA, 5 mA, *0 mA, *0 mA, *0 mA, **0 mA, **0 mA, **0 mA, 1 A, 2 A, 5 A, *0 A total *3 automatic ranges Stability: superior to 0.*5% Flux Range: 0.*5, 0.5, 1, 2, 5, *0, *0 mWb, total seven automatic ranges Sensitivity: 0.*5 μWb (ballistic method) 0.1 μWb (magnetic field sweep) | A / D Conversion: *6 bits, 8 channels differential input Conversion Time: < *0 μs Conversion Accuracy: 0.*1% (full range) D/A Conversion: *6 bits, 2 channels Conversion Accuracy: 0.*1% (full range) Bus Structure: PCI busbar |