Room 2904A, No. 1027 Changning Rd, Shanghai, Shanghai
These series of metallurgical and crane *-phase motor YZR,YZ
with wound and squirrel cage rotor are specially used to drive
metallurgical crane and other similar machines with better overload
capability and mechanical strength,therefore,it is suitable for
short time duty or intermittent period duty and equipments with
frequent starting and braking or distinct vitration and impact.
The standard range of power output and mounting dimensions are in
comply with the reconmended standard of IEC *2,the relation between
range of power output and mounting dimensions are similar to
standard JEM***2 and West Germany standard DIN****1,so that most of
them can be interchanged.
The motor can work well when the altitude does not exceed
***0m.
There are two classes of F and H insulation,Class F is applicalbe
to suit temperature which cool air does not exceed *0 under normal
condition,Class H is suitable for metallurgical sites when ambient
temperature no exceeding *0 both motors have same data.
The motors possess better enclosure,degree of protection IP*4 for
normal site condition,and IP*4 for metallurgical condition.
YZR,YZ series metallurgical and crane motor
Motor's rated voltage and frequency is **0V,*0HZ.
Speed;***0rpm ***0rpm **0rpm **0rpm
Protection Class: IP*4 IP*4
Ambient Temperature:Ambient temperature not exceeding *0℃ (for crane uses) or *0℃ (for metallurgical uses)
Altitude: not exceed ***0 Meter
Rated Frequency: *0Hz/*0Hz
Insulation Class: F
Temprature rise: B
Cooling:Frame ******2: IC***1 Frame: ******5 IC***1 Frame; **0 IC***1
Working Duty: S2,S3,S4,S5
1.Short-time duty type (S2)
Operation of constant load during a given time, less than that
required to reach thermal equilibrium, followed by a rest and
de-energized period of sufficient duration to re-establish machine
temperature within 2 deg K of the coolant.
2. Intermittent periodic duty type (S3)
A sequence of identical duty cycles, each including a period of
operation at constant load and a rest and de-energized period but
the operation period are so short that it is not sufficient for the
machine to reach thermal equilibrium In this duty type, the cycle
is such that the starting current does not significantly affect the
temperature rise.
3. Intermittent periodic duty type with starting (S4)
A sequence of identical duty cycles, each including a significant
period of starting, a period of operation of constant load and a
rest and de-energized period, but the operation period are so short
that it is not sufficient for the machine to reach thermal
equilibrium.
4. Intermittent periodic duty type with electric braking (S5)
A sequence of identical duty cycles, each consisting of a period of
starting, a period of operation at constant load and a rest and
de-energized period, but the operation period are so short that it
is not sufficient for the machine to reach thermal
equilibrium.