Description
System function
Throughput: up to **0 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at any
time. Test sequence can be sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes,
maintenance free
Cuvette washing: auto wash the cuvettes through 6 segments washing
pipe and continuous usethem,
and each cuvette wash *2 times before use it again
Reaction detect: monitor *1 cuvettes’s reaction at the same
time
Photometric process: the interval
time between two consecutive photometric points are exactly
thesame
Pipeline system: pressure auto released pumps and double filters to
protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning
of moving parts
Environmental resistance: resistant form dust and water
vapor
Sample/Reagent/Stirrer system
Sample volume: 2μL~*0μL, step by 0.1μL
Sample disc: *0 positions for primary tubes and secondary
cups
Sample probe: inner and outer walls are highly polished leads
carry-over<0.1%,
level detectionand
vertical and horizontal collision protection
Sample tube: both primary tubes and secondary cups are
suitable
Reagent volume: *0μL~**0μL, step by 1μL
Reagent disc: provide *0 reagent bottle positions
Reagent probe: inner and outer walls are highly polished leads
carry-over<0.1%,
level detectionand
vertical and horizontal collision protection
Reagent bottle: particular
reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the
principle of peltier
Stirrer: paddle stirrer coated with Teflon, stir immediately after
the sample was added in
Water consume: <6L/hour
Carry over: Optimized item test sequence and reinforced washing
process, lower the carry overand
avoid probe being clotted
Reaction system
Cuvette: permanent UV free glass cuvette
Reaction disc: Discal
reaction disc with *1 disposable cuvettes
Reaction volume:**0μL~**0μL
Heater: solid and sealed heater leads temperature raise rapidly and
steady and maintenance free
Temperature: *7℃±0.1℃
Optical system
Light source: *2V *0W, halogen lamp with lifetime more than ***0
hours
Spectrometer: post spectrometer with arrayed and sealed filters,
maintenance free
Wavelength: **0nm, **5nm, **0nm, **0nm, **6nm, **8nm, **0nm,
**0nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear, two points linear,
multi-points linear, Logit*4P, Logit*5P, Spline, Exponential 5P,
Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC, daily QC, day to day QC
QC chart: L-J, Cumulative
sum check, Twin Plot
QC rule: Customized QC rule in order to adapt different item’s
requirements
Operational system
Operational system: VISTA, Windows XP, Windows***0
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the
analyzer
Power/ Dimension
Voltage: AC *5V~**4V, *5Hz±8Hz,
Auto adapt according to the input voltage
Power Consume: ≤**0VA
Dimension: 9*0mm×**2mm×***0mm
(L×W×H)
Net weight: **0Kg