Sell Super External Counter-Pulsation Device (SECP II)

Sell Super External Counter-Pulsation Device (SECP II)

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

-

Minimum Order Quantity:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

T/T, L/C

Contactar ahora
Miembro Básico

Persona de contacto Mr. EECP

NO.18, 2nd Hanxi Industrial Zone, Zhongcun, Panyu, Guangzhou, China, Guangzhou, Guangdong

Contactar ahora

Description


Product: Super External Counter-Pulsation Device (SECP)
USAGE:
The device can be used for the treatment of:
(1).Coronary heart disease, angina pectoris and myocardial infarction.
(2).Cerebral arteriosclerosis, cerebral thrombosis, cerebral embolism, paralysis agitation, cerebral ischemia of vertebral-basilar artery, sequel of cerebrovascular accident and other encephalopathy caused by ischemia.
(3).Embolism of retinal artery, central serous retinopathy, and optic atrophy and nerve disease for shortage of blood.
(4).Sudden deafness.
(5).Other ischemic diseases and sequels caused by arteriosclerosis and disturbance of circulation, therapy after operation of coronary bypass.
(6).Tiredness due to excessive physical exercise.
(7).Rehabilitation and health-care purposes.

Technical Specification

1. Common mode rejection ratio (CMRR): not less than *0 dB(resolution).
2. Automatic pick-out of the QRS, gating limit at the input terminal, not greater than 0.*5 mV. Both positive and negative EC can be detected.
3. Automatically tracing the irregular heart rate, and making possible synchronized counter-pulsation.
4. In case of premature pulsation or delayed deflation, QRS wave triggers the deflation automatically.
5. In case of patients heart rate is lower than *2 beats/min., the parameter of heart rate on screen becomes red and the ECPT stops automatically, ECPT recovers when the heart rate is normal.
6. At ADULT , in case of premature pulsation or the patients heart rate exceeds **5 beats/min., the parameter of heart rate on screen becomes red and the ECPT stops automatically, and ECPT recovers when the heart rate is normal.
7. The device has 5 adjustable settings for simulated EC waves (inner triggering square waves) i.e. *0,*0,*0,**0,**0 beats/min.. In case of turning on or reset, the default setting is *0 beats/min..
8. The device has 9 adjustable settings for treating time, i.e. *0,*0,*0,*0,*0,*0,*0,*0,*0 minutes. In case of turning on, reset or restoration of power supply, the default setting is *0 minutes.
9. The monitor displays:
(1)Heart rate and starting time of inflation and deflation.
(2)Treating time, pulse wave peak ratio: h2 : h1 and area ratio: Area 2 : Area 1.
*0. Two settings for counter-pulsation ratio: 1:1 : 1:2.
*1. Digital filtering restrains the sine *0 Hz interference signals from EC input.
*2. *-trace, *-signal monitor displays the cardiac signal, inflation/deflation signal and pulse waveform synchronously.
*3. Limiting inflation time against positive pulsation function is provided.
*4. 2 scanning speed settings: *5mm/s and *0 mm/s are provided.
*5. Electric-control of pressure regulation.
*6. Automatic stop of the pump at the end of treatment.
*7. Automatic deflation at the end of the treatment .
*8. Power consumption:

    Control Console    : **0V  *0/*0Hz     **0W
                                                                                                                      **0V  *0/*0Hz    ***0W

Air pump(in the bed)   : **0V  *0/*0Hz    ***0W

*9. The inflation range (positive pressure) is  not lower than  **0.*4MPa, negative pressure is used for deflation.
*0. Upper limit of air-pressure automatically controlled.
*1. The turn-off buttons for patient in emergency are fitted at each side of the device.

PRINCIPLE
During the treatment, the specially made inflatable balloon cuffs are wrapped and fastened to the extremities and buttocks of the patient. When the heart in the diastolic stage, the air goes into the cuffs in sequence, and compresses the artery by cuffs, so that the blood in diastolic stage can concentrate to the upper part of the body, which increase the blood volume of the heart, and promote the set up of the collateral circulation gradually. After the close of arterial valves, through the deflation of the air in the balloon cuffs, the compressed artery is thus immediately release, so that  it may receive the blood driven from the heart, hence the device decreases the after-load of the heart, and reduces the systolic pressure, which has the therapeutic effect on all kinds of cardiac vascular and cerebrovascular diseases caused by myocardial and cerebral ischemia.

Enhanced External Counterpulsation (EECP)