Product: Super External Counter-Pulsation
Device (SECP)
USAGE:
The device can be used for the treatment of:
(1).Coronary heart disease, angina pectoris and myocardial
infarction.
(2).Cerebral arteriosclerosis, cerebral thrombosis, cerebral
embolism, paralysis agitation, cerebral ischemia of
vertebral-basilar artery, sequel of cerebrovascular accident and
other encephalopathy caused by ischemia.
(3).Embolism of retinal artery, central serous retinopathy, and
optic atrophy and nerve disease for shortage of blood.
(4).Sudden deafness.
(5).Other ischemic diseases and sequels caused by arteriosclerosis
and disturbance of circulation, therapy after operation of coronary
bypass.
(6).Tiredness due to excessive physical exercise.
(7).Rehabilitation and health-care purposes.
Technical Specification
1.
Common mode rejection ratio (CMRR): not less than *0
dB(resolution).
2. Automatic pick-out of the QRS, gating limit at the input
terminal, not greater than 0.*5 mV. Both positive and negative EC
can be detected.
3. Automatically tracing the irregular heart rate, and making
possible synchronized counter-pulsation.
4. In case of premature pulsation or delayed deflation, QRS wave
triggers the deflation automatically.
5. In case of patients heart rate is lower than *2 beats/min., the
parameter of heart rate on screen becomes red and the ECPT stops
automatically, ECPT recovers when the heart rate is normal.
6. At ADULT , in case of premature pulsation or the patients heart
rate exceeds **5 beats/min., the parameter of heart rate on screen
becomes red and the ECPT stops automatically, and ECPT recovers
when the heart rate is normal.
7. The device has 5 adjustable settings for simulated EC waves
(inner triggering square waves) i.e. *0,*0,*0,**0,**0 beats/min..
In case of turning on or reset, the default setting is *0
beats/min..
8. The device has 9 adjustable settings for treating time, i.e.
*0,*0,*0,*0,*0,*0,*0,*0,*0 minutes. In case of turning on, reset or
restoration of power supply, the default setting is *0 minutes.
9. The monitor displays:
(1)Heart rate and starting time of inflation and deflation.
(2)Treating time, pulse wave peak ratio: h2 : h1 and area ratio:
Area 2 : Area 1.
*0. Two settings for counter-pulsation ratio: 1:1 : 1:2.
*1. Digital filtering restrains the sine *0 Hz interference signals
from EC input.
*2. *-trace, *-signal monitor displays the cardiac signal,
inflation/deflation signal and pulse waveform synchronously.
*3. Limiting inflation time against positive pulsation function is
provided.
*4. 2 scanning speed settings: *5mm/s and *0 mm/s are provided.
*5. Electric-control of pressure regulation.
*6. Automatic stop of the pump at the end of treatment.
*7. Automatic deflation at the end of the treatment .
*8. Power consumption:
Control
Console : **0V
*0/*0Hz **0W
**0V *0/*0Hz ***0W
Air pump(in the bed) : **0V *0/*0Hz ***0W
*9.
The inflation range (positive pressure) is not lower
than **0.*4MPa, negative pressure is used for deflation.
*0. Upper limit of air-pressure automatically controlled.
*1. The turn-off buttons for patient in emergency are fitted at
each side of the device.
PRINCIPLE
During the treatment, the specially made inflatable balloon cuffs
are wrapped and fastened to the extremities and buttocks of the
patient. When the heart in the diastolic stage, the air goes into
the cuffs in sequence, and compresses the artery by cuffs, so that
the blood in diastolic stage can concentrate to the upper part of
the body, which increase the blood volume of the heart, and promote
the set up of the collateral circulation gradually. After the close
of arterial valves, through the deflation of the air in the balloon
cuffs, the compressed artery is thus immediately release, so
that it may receive the blood driven from the heart, hence
the device decreases the after-load of the heart, and reduces the
systolic pressure, which has the therapeutic effect on all kinds of
cardiac vascular and cerebrovascular diseases caused by myocardial
and cerebral ischemia.
Enhanced External Counterpulsation (EECP)