¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Pulse Oximeter MK50E CE FDA

Sell Pulse Oximeter MK50E CE FDA

|

Minimum Order

Place of Origin:

Hebei ,China

Price for Minimum Order:

-

Minimum Order Quantity:

-

Packaging Detail:

Carton

Delivery Time:

in five days after receipt of payment

Supplying Ability:

-

Payment Type:

T/T, PayPal, Other

Contactar ahora
Miembro Básico

Persona de contacto Ms. Zhou

Hebei Avenue 114, Haigang Zone , Qin huangdao, Heibei, China, Qinhuangdao, Hebei

Contactar ahora

Description


Instructions
Principle of the MK*0E Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Major Features
â—† Integrated with SpO2 probe and processing display module
â—† Small in volume、light in weight and convenient in carrying
â—† Operation of the product is simple ,low power consumption
â—† Operation menu for the function setting
â—† SpO2 value display
â—† Pulse rate value display, bar graph display
â—† Pulse waveform display
â—† The display mode can be changed
â—† Screen brightness can be changed
â—† A pulse rate sound indication
â—† With measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustable
â—† Battery capacity indication
â—† Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage,and
with alarm function
◆ With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers)
◆ Real-time data can be transmitted to computers
◆ Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe.
◆RF Wireless communication function(option)(only applied for Ver6.6R or above )
◆ Connected with an external oximeter probe(option)(CMS*0EW,only applied for Ver6.6R or above of CMS*0E
 

Main performance
 
  â—† Display Mode:1.3" *5K Color OLED display
   â—†Screen Resolution:**8**6
◆ SpO2 Measuring Range:0%~**0%, (the resolution is 1%).
◆ Accuracy:*0%~**0%:±2% ,Below *0% unspecified.
◆ PR Measuring Range:*0bpm~**0bpm, (the resolution is 1bpm)
◆ Accuracy:±2bpm or ±2% (select larger)
◆ Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
◆ Resistance to surrounding light: The deviation between the value measured in the condition
◆ of man-made light or indoor natural light and that of darkroom is less than ±1%.
◆ Power Consumption:less than **0mA
◆ Voltage:DC 3.6V~4.2V
◆ Power Supply:Voltage 3.7 rechargeable lithium battery × 1 
◆ Battery working hour:*0 hours
◆ Battery working life:Charge and discharge no less than **0 times.
 â—†Safety Type:Interior Battery,BF Type

Accessories
Sell in standard
◆ a hanging rope
◆ a user manual
◆ a data line
◆ a disk (PC software)
◆ a power adapter (GTM*********5;CMS***5)
Sell in addition
Oximeter Probe(Refer to probe application instruction for details and notice renewal)
RF Wireless Module(only applied for Ver6.6R or above of MK*0E)

Physical Identity
Dimension:*7(L) × *2(W) × *0 (H) mm
Weight:About *0g (with the lithium battery*1)

Send a direct inquiry to this supplier

A:

Ms. Zhou < Makcom Medical Electronics Co , .ltd >

quiero saber: