N530 for the detection of gas permeability of various films, infusion bags and other packaging materials for O2, CO2, N2 and other gases through the barrier properties. It is designed and manufactured according to the standards of ISO ********1, ISO******1, GB / T ********0, ASTM D******2 (***3), YBB*******3 .It has three independent testing chambers and independent temperature control system. The core is connected with computer through the USB. It can automatically judge and stop testing . The testing result is stable, curves of permeability rate ,temperature, pressure and different pressure will be shown at the same time. The test report will generate automatically while the data automatically stored. It also support TCP/IP protocol. There are three measuring range that can be enlarged.
Test principlesN 530 Gas Permeation Analyzer designed using the principle of differential pressure method, preparation samples will be placed between in the test chamber with high / low pressure , and clamping it ,then make the whole test system to have a vacuum processed, input test gas the high-pressure test chamber to ensure on both sides of the test samples have a constant pressure, the gas under the role of pressure pass through film from high-pressure chamber to the low pressure chamber to infiltrate, observe the changes pressure in low-pressure chamber to caculate barrier parameters of the sample.
Software Interface
Specifications
Measuring range: 0.*2 ~ ****0 cm3/m2 • day • 0.1Mpa (Through the expansion of volume cap can test *****0 cm3/m2 • day • 0.1Mpa) Measurement Accuracy: 0.*1cm3/m2 • day • 0.1MPa Temperature range: *5 ~ *5 ℃ (standard temperature of *3 ℃) Temperature Accuracy: ± 0.*1 ℃
Vacuum accuracy: 0.1Pa Test pressure:*0.1Mpa ~ *0.1 Mpa Test gas: O2, CO2, N2 and other gases Air Pressure: 0.1Mpa ~ 0.8Mpa Specimen size: Φ*0mm, through an area of *0.*4 cm2 Sample: 3(extension up to more pieces)
Carrier gas interface: 1 / 8 inch
Sample thickness: ≤ 2mm Power: AC **0V /*0HZ
Instrument weigh : *5 Kg.
Gloss weight: *0 Kg.
Dimension : *0 cm×*6 cm×*0 cm
Features
1. Computer automatically control three chambers of testing ,can test different samples, Configuration three independent sensors, each chamber can be set different temperatures. First creating positive and negative pressure dual-mode testing, leading international standard.
2.The sample can be tested by single chamber, or double chambers or three chambers .
3. Seperately show the