Description
Features:
1. Fully automated, Discrete, Random access
2. Total open setting of items, supported different reagents from
different countries.
3. Reversed optics and imported photosensor make sure the precision
of detection results.
4. Microsring injector imported from Germany assures the veracity
of a trace of samples, sample step by 0.1 UL, reagent step by1
UL
5. *4 hour non-stop working, convenient emergency function with
inserting emergency at random.
6. Implementing analysis of ultra-trace reaction solution to **0
UL, and saving more reagents.
7. Discrete cuvette, preventing from cross-infection, and be washed
and reused, making sure accurate result and save cost.
8. Perfect self-detection function makes sure the analyzer in order
and accurate result.
9. Software is easy to learn and use. And test report can be
printed.
*0. Perfect function of quality control management is convenient
for users to manage the clinical test result.
*1. Detecting in the whole reaction process with reaction curve,
convenient for users to monitor thoroughly and scientifically
analyze the detection data.
*2. Supporting software can implement the function of detecting
surplus reagent through liquid level induction of reagent
probe.
Reference Pictures and Illustrations
I. *0 sample positions for primary tubes or serum cups, sufficient
to meet the demand for use
II. Adopting state-of-the-art pattern of cleaning, washing cuvettes
automatically, as well as recording and deducting the base value of
each cuvette, meanwhile eliminating differentials between
cuvettes.
III. *5 reagent positions, non-break refrigerating system with
independent switch.
IV. High sensitive liquid level induction system, automatic liquid
level detection, collision protection, automatically cleaning
inside and outside of probes and wave-poured washing canal, make
sure wash probe clean. Hydrophobic membrane treatment for both
inside and outside and no cross-infection.
V. High precision Microsring injector is imported from Germany.
Special glass is adopted in the inner wall, and makes sure sample
precision and resistant to abrasion, meanwhile solid organic glass
is adopted in the outer wall. Precision for sample injector can
reach 0.1 UL, and for reagent injector can reach 1 UL. Sample
injector can absorb sample volume from 2 to *0 UL each time and the
minimum limit for sample can reach 2 UL.
Model BIOBASE-DIAMOND
Dimensions (W x D x H) ***0***0****0
Analysis method End point, two points, kinetic method,
turbidimetry
Wavelength range **0, **5, **0, **6, **8, **0, **0, **0(three of
them can be defined by the users), adopting reversed optics
Reagent volume R1: *****0 ul; R2: *****0 ul(step by 1 ul), support
reagent from different countries
Receiver 8 imported photo receivers
Sample volume 3 ul**0 ul (step by 0.1 ul), high precision injector
(dilution vessel) is prepared
Cuvette **0 independent reaction cuvettes(optical path length
6mm)
Calibration one-point, multipoint
Test/H **0
Shipping Dimensions,
(W x D x H) ***0***0****0
Software Windows ***0 professional or windows XP. Have plenty of
functions of inquiries, convenient to use
Printout user can modify the printing format by his own
Electrical AC**0V + *2V *0Hz + 1Hz
Certification CE, ISO***1, ISO****1, ISO****5, FDA