Electronic plastic waste in the halogen content is much higher than ordinary plastic, so the first thing is how to control dioxins and halogenated hydrocarbons in the formation and emission, high-temperature combustion can reduce formation of dioxins, the complete combustion of degree and is also related to the generation of halogenated hydrocarbons, general requirements [3] the combustion chamber outlet temperature control **0 ℃ ~ **0 ℃, the concentration of dioxin emissions to meet the standards, to reduce the dioxins and other halogenated hydrocarbons way is to flue gas temperature (above 1 **0 ℃) decomposition process, combustion technology for the security of e-waste burning, to ensure decomposition of halogenated hydrocarbons, preferably the secondary combustion chamber temperature can be controlled in ***0 ℃, the residence time of not less than 1 second. In either approach, the final emissions must be rapidly cooled to quench way to avoid harmful substances below **0 ℃ re-formation.