¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell 33KV current transformer

Sell 33KV current transformer

1260 / Piece

|

Minimum Order

Place of Origin:

China

Price for Minimum Order:

Minimum Order Quantity:

1 Set

Packaging Detail:

plywood box

Delivery Time:

30 days after receiving down payment

Supplying Ability:

1000 Piece per Month

Payment Type:

T/T, L/C, Western Union, PayPal

Contactar ahora
Miembro Básico

Persona de contacto Mr. Yu

Room 5B1, No. 1, Xinghuo Road,Fengtai Dist, Beijing, Beijing

Contactar ahora

Description

  1. Advantages: Dry-type insulation No oilfilling, no gasfilling, no ceramic Antipollution Easy operation and maintenance   2. Type:
  LGB- 1
    L: CT, Current Transformer
    G: dry type,no-filling
    B: with protection winding
    1: rated voltage, kV
3. service conditions
  Ambient air temperature: –*0 centigrade ~ **0 centigrade
  The altitude: ≤***0m,if higher,amend according to IEC ****4
  The creepage ratio: *0mm/kV, *5mm/kV or *1mm/kV
4. Technical indexes
  Rated voltage:  *3kV
  Partial discharge:  ≤5pC
  Dielectric dissipation factor:  ≤0.**4
  Ith: *0 kA,  Idyn: **5 kA
  Rated primary current:  ≤***0A
  Rated secondary current:  5A or 1A
  Rated output capacity:  ***0VA
  Accuracy limit factor: 5, *0, *5, *0, *0, *0, *0
  Accuracy classes for measuring core: 0.2, 0.2S, 0.5, 0.5S
  Accuracy classes for protective core: 5P, *0P, 5PR, *0PR, TPY
  All parameters are in accordance with IEC ******1
1.Use

LGBJ**3 current transfromer can be applied to wet or dry tropical zone and highland places.

2. Standards

IEC standard: IEC ******1,ISO***1

National Standard: GB***8 ,GB**1.1 Insulaiton co-ordination for high voltage transmission and distribution equipment

3. Service Condition

Ambient Temperature: **0oC~**0oC

Altitude: ≤***0m,if higher,amended according to IEC ****4
Creepage ratio: *0mm/kV, *5mm/kV or *1mm/kV

4. Earthing method

The neutral is solidly grounded

5. Advantages:

  •   dry type isolation with the silicone rubber skirt.
  •   no oilfilling, no gasfilling, no ceramic
  •   high ability of antipollution, easy operation, no maintenance
  •   the current ratio can be changed easily by changing the connection method in shielding enclosure  to facilitate the realization of series or parallel connection.
  •    the grading cover  is aluminum alloy casting formed and the cabinet is stainless steel plate drawing formed, use DACRAL(Zinc/Chromate coatings) for resistance to corrosion, which has a good level of corrosion resistance
  •   the electric field is evenly distributed, and the partial discharge is small amount and stable, small dielectric loss.

     