FOB Price
Obtener el precio más reciente|
Minimum Order
Place of Origin:
The Netherlands
Price for Minimum Order:
-
Minimum Order Quantity:
1
Packaging Detail:
-
Delivery Time:
-
Supplying Ability:
5000 p/month
Payment Type:
-
Netherlands
Persona de contacto Mr. George
Molenbaan 19, Capelle aan den IJssel, Zuid-Holland
BRESLE KIT - CHLORIDE TEST KITThe TQC Bresle Kit - Chloride Test Kit complies with the ISO *****6 and ISO *****9 standards that describe the Bresle Method to assess the level of soluble salts using a patch, distilled water and a conductivity gauge. The conductivity is mainly directly proportional to the concentration of dissolved chloride ions in the solution. The kit includes all the necessary equipment to execute a bresle test that will indicate the contamination of soluble salts on blast-cleaned surfaces prior to coating. Inside the Bresle Kit - Chloride Test Kit is a conductivity gauge used for the assessment of soluble salt ions as chlorides, sulphates and nitrates. Contamination of blast-media The TQC Bresle Kit - Chloride Test Kit is also suitable to determine the contamination of blast-media in use. This important test described in the ISO ******6 and ISO ******7 standards helps to prevent that the dissolved salts in the recycled abrasive media or water will not re-contaminate the surface being cleaned. SP***0 TQC Bresle KIT- Chloride Test KIT Supplied with: digital conductivity meter, *5x bresle patch, 6x *5ml beaker, **0ml distilled water, *0ml syringe with needle, calibration and rinse solution. TQC DSP Methode The new Direct Sample Procedure eliminates the use of the *5ml measurement solution. Measurements can now directly be made in the solution that is extracted from the patch, eliminating the dilution step. This not only increases efficiency but also eliminates the most error sensitive part of the old procedure. To achieve this there is only 2.5 ml of deionised water injected in the patch. This also reduces the calculation factor to 1. The reading from the gauge doesn’t have to be multiplied anymore to get the soluble salt measured as sodium chloride concentration in mg·m*1. Due to the measurement in the gauges own measuring cell all static disturbance is also eliminated. Increasing the reliability of the analyses even further.