FOB Price
Obtener el precio más reciente|
Minimum Order
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
-
Packaging Detail:
-
Delivery Time:
-
Supplying Ability:
-
Payment Type:
-
Persona de contacto Ms. Bonnie
Baiyun Road, guangzhou, guangdong
Contactless! The voltage to be measured is inspected in the above No bare metal conductor, assure absolute safety clamp the wire about **0mm2 gain time, increase productivity Super induction slope mo alloy clamps, sensitive and reliable Inspect the live wire of wire, Inspect electricity simplely , judge lacks, search breakpoint, maintenan line Shutdown automatically , reduce the consumption of battery Low power consumption, canwork about *0 hours continuously Phase Detector ETCR ***0A This is a phase detector, designed to perform phase sequence checks and live line checks of a *-phase circuit using a static induction voltage clip. • The static induction voltage clips are used to be able to clip on a cladded wire. • It is small with a CAT â…¢ **0V safety rating. • Red LED lamps are used to make the indication visible in dimly lit areas. • The direction of phase sequence can be checked easily using the LED lamps, which blink in order. Basic Specifications Function Phase detection (positive/negative) Voltage detection method Static induction Object to be connected Insulated wire (nominal sectional area of the conductor: 2 to **0 mm², finished outer diameter: up to ø *7mm) Performance-guarantee voltage range *-phase, *0 to **0 VAC (sine waveï&frac*4;Œcontinuous) Operating frequency range *5 to *6 Hz Display Phase-detection indication Positive phase sequence: The four phase-sequence lamps blink order (clockwise) and the buzzer sounds intermittently. Negative phase sequence: The four phase-sequence lamps blink in order (counterclockwise) and the buzzer sounds continuously. Line-voltage indication R-S lamp, S-T lamp Power indication Power ON lamp: lights up (Power ON) blinks (Battery Low) General Specifications Operating temperature and humidity 0 to *0℃(*2 to **4℉), *0%RH or less ( with no condensation) Storage temperature and humidity **0 to *0℃(*4 to **0℉), *0%RH or less (with no condensation) Location for use Altitude up to ***0m(***2 feet), indoors Maximum rated voltage to earth **0V Dielectric strength 5.4kVrms Power supply Rated supply voltage 1.5VDC×2 Two “AA†size batteries Maximum rated power **0Mva Continuous operating time* Approx.*0 hours(Power ON, Standby state, using R6P manganese battery) *Battery life Auto Power Off (This function can not Be canceled.) The power will be turned off automatically if the Instrument remains idle for *5 minutes after the power is turned on. To reset, turn the power on again using the Power ON switch. Options Carrying case, Strap*, Spiral tube*, Instruction manual, Two R6P manganese batteries. *Attaching as the occasion demands. Cable length Approx.0.7m(*7.*6) Dimensions and mass Approx.*0W×*5H×*0Dmm(2.*6W×2.*5H×1.*8D) (excluding projections), Approx.**0g(7.1oz) Applicable standards Safety EN******1:***1, EN********1:***2 Pollution degree2, Measurement category CAT III(**0V)(anticipated transient overvoltage ***0V) EMC EN****6:***7+A1:***8+A2:***1