¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
CMS 9000 Multi-parameter Patient Monitor

CMS 9000 Multi-parameter Patient Monitor

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

-

Minimum Order Quantity:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Contactar ahora
Miembro Básico

Persona de contacto Ms. Sarah

Huanghe West Road 24, E&T Development Zone, Qinhuangdao, Hebei

Contactar ahora

Description

Features ■ Color TFT Screen, waveform up to 8 channels ■ Light and portable with build-in rechargeable battery ■ UP to *0 kinds of monitor parameters ■ Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis ■ *2 hour storage and review of trend grams and tables, *0 second review of olographic wavefo rms. ■ Built-in recorder(option) ■ All-round monitor of adult , pediatric and neonatal. ■ Electrosurgical unit and defibrillation protected ■ Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature, Pulse rate ■ Option parameters: EtCO2, CO, IBP, Thermal Printer ECG ■ *-lead or *-lead selectable ■ Input: *-lead: RA; LA; RL; LL; V or R; L; N; F; C ■ Lead selection: I; II; III; avR; avL; avF; Vx; CAL ■ Gain selection: *2.5mm/s, *5mm/s, *0mm/s ■ Accuracy: ±1bpm or ±1%, whichever is greater ■ Protection: Withstand ***0VAC/*0Hz voltage in isolation against electrosurgical and defibrillation ■ Calibration signal: 1mV±5% ■ Operation modes: Diagnostic, Monitor, Surgery ■ Alarm range: Adult: *****0bpm ■ Pediatric/Neonatal: *****0bpm ■ Alarm range: *2.0mV~2.0mV ■ S-T detection: YES, Arrhythmia analysis: YES ■ Alarm: YES, audible and visual alarm, alarm events recallable NIBP ■ Method: Oscillometry ■ Operation modes: Manual/Automatic/STAT ■ Measurement unit: mmHg/KPa selectable ■ Measurement types: Systolic, Diastolic, Mean ■ Measurement range: Adult: *****0mmHg ■ Over-pressure protection: YES ■ Resolution: 1mmHg ■ Accuracy: Mean error and standard deviation per ANSI/AAMI SP**0 ■ Alarm: Systolic, Diastolic, Mean SpO2 ■ Measurement range: ****0% ■ Accuracy: ±2digit (*0~**0%); ■ 0~*9% unspecified ■ Alarm range: ****0% Respiration ■ Method: RA-LL impedance ■ Pediatric/Neonatal: ****0rpm ■ Alarm range: Adult: ****0rpm ■ Pediatric/Neonatal: ****0rpm ■ Apnea alarm: YES Temperature ■ Resolution: 0.1℃ ■ Channel: Dual-channel ■ Alarm range: ***0℃ Option: EtCO2 ■ Measurement Mode: Side-stream or mainstream ■ Measurement range: EtCO2: ***9mmHg ■ Accuracy: CO2 concentration ■ Apnea alarm: YES CO ■ Method: Thermo-dilution ■ Measurement range: CO: 0.***0 lit./min. IBP ■ Channel: 2 channels ■ Pressure transducer: Sensitivity: 5( mV/V/mmHg) ■ Transducer sites: ART, PA, CVP, RAP, LAP, ICP ■ Alarm range: **0~**0mmHg

Send a direct inquiry to this supplier

A:

Ms. Sarah < Contec Medical Systems >

quiero saber: