FOB Price
Obtener el precio más reciente|
Minimum Order
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
-
Packaging Detail:
-
Delivery Time:
-
Supplying Ability:
-
Payment Type:
-
Persona de contacto Mr. Jack
Yaohai Industrial Park, Hefei, anhui
PVC insulated sheath control cable Specification Details Main application KVV Copper conductor PVC insulated and sheathed control cable For laying indoors, intranches and in ducts, for fixed installation KVVP Copper conductor PVC insulated and sheathed copper wire braiding screened control cable For laying indoors, intranches and in ducts, for fixed installation KVVP2 Copper conductor PVC insulated and sheathed control cable with steel tape shield For laying indoors, intranches and in ducts, for fixed installation KVV*2 Copper conductor PVC insulated and sheathed control cable with steel tape armoured For laying indoors, in trenches, in ducts and in ground, able to withstand heavier mechanical force , and for fixed installation KVVR Copper conductor PVC insulated&sheathed flexible control cable For laying indoors, movable and flexible KYJV XLPE insulated and PVC sheathed control cable This cable is used as connection fixed-installed in the instruments and meters of distribution system rated voltage 0.6/1kv and below KYJV*2 XLPE insulated , steel tape armoured and PVC sheathed control cable This cable is used as connection fixed-installed in the instruments and meters of distribution system rated voltage 0.6/1kv and below KYJVP XLPE insulated , copper wire screened and PVC sheathed control cable This cable is used as connection fixed-installed in the instruments and meters of distribution system rated voltage 0.6/1kv and below ZR-KVVRP Copper conductor PVC insulated and sheathed copper wire braiding screened flexible flame retardant control cable For laying indoors with capability of moving and screening ZR-KVV Copper conductor PVC insulated and sheathed flame retardant control cable For laying indoors, intranches and in ducts, for fixed installation , the cable should be flame retardant ZR-KVVP2 Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield For laying indoors, intranches and in ducts, for fixed installation , the cable should be flame retardant ZR-KVV2 Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armour For laying indoors, intranches and in ducts, for fixed installation , the cable should be flame retardant and bear extremal mechanical force ZR-KVVR Copper conductor PVC insulated &sheathed flame retardant flexible control cable For laying indoors, the cable should be flame retardant flexible and movable ZR-KYJV XLPE insulated and PVC sheathed flame—retardant control cable This cable is used as connection fixed-installed in the instruments and meters of distribution system rated voltage 0.6/1kv and below ZR-KJJV*2 XLPE insulated , steel tape armoured and PVC sheathed flame-retardant control cable This cable is used as connection fixed-installed in the instruments and meters of distribution system rated voltage 0.6/1kv and below ZR-KYJVP XLPE insulated , copper wire screened and PVC sheathed flame-retardant control cable This cable is used as connection fixed-installed in the instruments and meters of distribution system rated voltage 0.6/1kv and below