¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
CO2 Detector_CDS2000 series CO2 Detector_CDS2000 series CO2 Detector_CDS2000 series
Next

CO2 Detector_CDS2000 series

30 ~ 50 / Set ( Negotiable )

|

100 Set Minimum Order

País:

South Korea

N º de Modelo:

CDS2000 series

Precio FOB:

30 ~ 50 / Set ( Negotiable ) Obtener el precio más reciente

Lugar de origen:

Republic of Korea

Precio de pedido mínimo:

30 per Set

Cantidad de pedido mínimo:

100 Set

Detalle de embalaje:

Carton or Box

El tiempo de entrega:

15 to 30 Days

Capacidad de suministro:

99999 Set per Day

Tipo de pago:

T/T, L/C, Other

Grupo de productos :

Contactar ahora
3rd Año

Persona de contacto Ms. Ella

309 Mokdong dong ro, Seoul, Yang Cheon Gu

Contactar ahora

Especificaciones del producto

  • Weight:Approx. 82g
  • Function:CO2 Detector, CO gas detectable
  • Feature:High sensitivity and good resolution
  • Warranty:Warranty period : 12 months

Descripción del producto

CO2 Detector_CDS2000 series
Description
[Carbon Dioxide(CO2), Carbon Monixide(CO), Particulate Matter(PM), Volatile Organic Compounds(VOCs), Temperature, Humidity]

CDS2000 is compact and easy-to-install IAQ(Indoor Air Quality) sensor, which is designed for carbon dioxide detecting devices in the air. This series is optimized to be used in specific applications such as building and house ventilation system and air conditioning system, which maintains acceptable levels of CO2 in the space by controlling the amount of fresh outdoor air.

• CDS2000 : CO2 Detector, Space type, 0~2,000ppm, 0 ~ 10Vdc / 0~20mAdc output
• CDS2000-L : CO2 Detector, Space type, 0~2,000ppm, LCD, 0 ~ 10Vdc / 0~20mAdc output, Relay output
• CDS2000_M : CO2 Detector, Space type, 0~2,000ppm, LCD, 0 ~ 10Vdc / 0~20mAdc output, Modbus output, Relay output
Features

• High sensitivity and good resolution
• Based on non-dispersive infrared(NDIR) technology
• Two types of analog signal (DCV and DCA) output (Selectable)
• Eliminates the need for manual calibration in most applications with ABC logic software
• On/Off relay output for CO2 limit monitoring
• Long term stability and lifetime (>10years)
• Optional Modbus communication
• Optional LCD display
• Low Power consumption
• Easy installation
• CE Certification
Advantages

• Manufactured in own factory
• Honeywell gas detector ODM supplier in Asia
Wiring Diagram
image
Specifications
Gas detected Carbon dioxide (CO2)
Sensing method NDIR (Non-dispersive infrared)
Detect range 0 ~ 2,000ppm
Accuracy ±30ppm ±5% of measured value
Power consumption 2W max.
Power supply 24Vac, 24Vdc±20%, 50/60Hz
Maintenance interval Not required
Output signal 0~10Vdc(default) or 0~20mA (selectable by jumper setting)
Modbus RTU
Relay(Alarm) output SPST relay, normally open, 1A/120Vac, 1A/24Vdc contact rating,
Activated at greater than 1,000ppm, deactivated at less than 900ppm
Coverage area Approximately 100m2
Response time Within 120 sec. (90% step)
Wiring 3 or 4 wires compatible
Optional Modbus

Hardware  : 2-wire RS-485
Software : Native Modbus MS/TP protocol (RTU or ASCII)
Baud Rate : Locally set to 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800 or 115200
Slave Address Range : Locally set to 0-64 (factory default is 1), (32 devices max on one daisy chain)

Operating temperature 0 ~ 50℃
Operating humidity 0 ~ 95%RH (non condensing)
Storage temperature -20 ~ 60℃
Storage humidity 0 ~ 95%RH (non condensing)
Sensor life expectancy >10 years
Housing material Plastic(ABS), Flame retarded acc. to UL94-V1
Caution on Use
• Do not use this device for outdoor use. This product is provided only for indoor use.
• Do not use this device for where a building is continuously occupied 24 hours per day, or where there could be significant sources of non-occupant related CO2 such as greenhouses, breweries and other industrial and food processing applications.
• Do not use this device for medical or safety purpose.
• Do not leave or use the device for longtime in a highly-damped place in which humidity is near 95%RH.
• The standard test condition in which the product was tested is 25℃±3℃, 50℃±30%RH. Signal may vary slightly by environment condition.
• This device must abide by the operating temperature/humidity and the storage temperature/humidity.
• Use the product when it is completely fixed and do not use it while it is in motion.
• We do not guarantee the performance of the device in the case of user installation, disassembling and inspection. When installing and inspection is necessary, please contact our technicians.
• NDIR sensor can be influenced by air pressure. It can be used without correction within 300M above the sea level. However, add the output value by +1.0% per 100M height above 300M.
Ex) If the output signal indicates 600ppm at the height of 500M, correct the output value to 630ppm by adding 30(600*0.01*5)ppm.
• Be careful when install and use the product as vibration, shock, and falling can cause a serious damage on the sensor.

 

País: South Korea
N º de Modelo: CDS2000 series
Precio FOB: 30 ~ 50 / Set ( Negotiable ) Obtener el precio más reciente
Lugar de origen: Republic of Korea
Precio de pedido mínimo: 30 per Set
Cantidad de pedido mínimo: 100 Set
Detalle de embalaje: Carton or Box
El tiempo de entrega: 15 to 30 Days
Capacidad de suministro: 99999 Set per Day
Tipo de pago: T/T, L/C, Other
Grupo de productos : Electronic
CO2 Detector_CDS2000 series
CO2 Detector_CDS2000 series
CO2 Detector_CDS2000 series

Send a direct inquiry to this supplier

A:

Ms. Ella < NICE D AND B Co., Ltd. >

quiero saber: