Test principle: the static
volumetric method, gas adsorption;
Analysis Models: BET,
Langmuir, BJH, t-plot, DR, αs-plot, MP, HK, SF, and
NLDFT;
Measuring range: surface
area ≥ 0.**5M2/g, no upper limit; mesoporous and macroporous 2 _
**0nm; micropore size 0.*5nm _ 2nm; pore volume 0.***1 cm3/g, no
upper limit.
Sorption gas:N2 (high
purity); Ar, Kr, CO2, CH4, etc. available
Analysis Stations: 2
ports. One analysis station can test the micropore and the other
can test the mesorpore.
Sample Type: powders,
granules, fibers, flakes and other materials
Pressure Sensor:
***0torr (**3kpa), *0torr (1.*3kpa); 1torr (0.**3kpa) or 0.1torr
(0.***3kpa); accuracy≤± 0.*5%(P.S)
P0 tube: there is a
separate P0 tube in every analysis port, two in all, controlled by
a separate pressure sensor, completely separates from the analysis
port, real-time detecting the nitrogen saturation vapor pressure,
and participating in the theoretical calculation; also the
atmospheric method to determinate the P0
accurately;
Cold trap tube: sample
degassing system has a special cold trap device that can
effectively remove the water, hazardous substances and other
impurities, degassed from the special sample, and it can avoid the
contamination of the vacuum system;
Degassing system:
Parity, ectopic vacuum degassing pretreatment systems are
controlled by separate pressure sensors. Two samples can be
analyzed simultaneously, also two samples can be degassed in
degassing ports; two independent sample degassing stations are
separate from the sample analysis ports. The degassing system has
two independent heating packages, two independent temperature
control systems, which can be programmed by temperature control;
you can choose another four external vacuum degassing pretreatment
system;
Degassing temperature:
room temperature ***0℃, accuracy ± 1℃;
Nitrogen Partial
Pressure: P/Po 1×***8 _ 0.**8, the minimum resolvable relative
pressure 5 × ***7
Ultimate vacuum:≤ *0P*6
Pa(7.5×***9 torr),
mechanical pump and turbo molecular pump.
Pressure Accuracy:
≤ ± 0.*5% (P.S)
País: | China |
N º de Modelo: | JW-BK200B |
Precio FOB: | ( Negotiable ) Obtener el precio más reciente |
Lugar de origen: | Beijng, China |
Precio de pedido mínimo: | - |
Cantidad de pedido mínimo: | 1 Set |
Detalle de embalaje: | - |
El tiempo de entrega: | 30 days |
Capacidad de suministro: | 1000 Set per Year |
Tipo de pago: | Other, PayPal, D/P, L/C, T/T |
Grupo de productos : | Static Volumetric Method |