Precio FOB
Obtener el precio más reciente1900 ~ 2000 USD / Set
|1 Set Minimum Order
País:
China
N º de Modelo:
Glo-m5
Precio FOB:
1900 ~ 2000 USD / Set Obtener el precio más reciente
Lugar de origen:
China
Precio de pedido mínimo:
1900 per Set
Cantidad de pedido mínimo:
1 Set
Detalle de embalaje:
The wooden case
El tiempo de entrega:
10 days
Capacidad de suministro:
100 Set per Month
Tipo de pago:
T/T, L/C, D/A, D/P, Western Union, Money Gram
Grupo de productos :
-
Persona de contacto Jerry
Shanghai, Shanghai
QUICK DETAILS
Constant temperature and humidity test chamber is also called constant temperature and humidity tester, constant temperature and humidity test chamber, programmable wet and heat alternating test chamber, constant temperature machine or constant temperature and humidity chamber. It is used to test the performance of materials in various environments and test equipment. The material is resistant to heat, cold, dry and moisture. For electronic, electrical appliances, mobile phones, communications, meters, vehicles, plastic products, metals, food, chemicals, building materials, medical, aerospace and other products used for testing quality.
FUNCTIONS
The constant temperature and
humidity test chamber consists of thermostat (warming, cooling)
and humidification. Through the rotating fan mounted on the top
of the box, the air is discharged into the box to realize gas
circulation, and the temperature and humidity inside the box are
balanced. The data collected by the built-in temperature and
humidity sensor of the box is transmitted to the temperature and
humidity controller (micro The information processor) performs an
edit process and issues a thermostat/humidity command through the
air heating unit, the condenser, and the heating evaporation unit
in the water tank.
Constant temperature and humidity box temperature adjustment is
through the box built-in temperature sensor, collect data,
adjusted by the temperature controller (micro information
processor), turn on the air heating unit to increase the
temperature or adjust the cooling solenoid valve to reduce the
temperature in the box, Meet the temperature required for
control. The humidity control of the constant temperature and
humidity box is through a built-in humidity sensor, collects
data, is regulated by a humidity controller (micro information
processor), and is connected to a water tank heating element to
increase the humidity in the tank or adjust refrigeration by
evaporating the water in the water tank. Solenoid valve to
achieve dehumidification in order to achieve the control of the
required humidity.
The constant temperature and humidity box is provided with
multiple protection measures; the temperature system is equipped
with an over-temperature protection device under the condition
that the maximum allowable safety temperature can be set, and the
air heating element can be automatically shut down when the
rotation fan stops; the humidification system can follow the
humidification tank water level. The power supply is reduced and
the power supply is stopped; the refrigeration system also stops
working as the temperature of the cabinet increases (more than
*0°C) or the humidity increases.
OPERATING PRINCIPLES
Through three interconnected
systems: refrigerant circulation system, air circulation system,
electrical automatic control system.
1. the constant temperature and humidity test chamber The
refrigerant circulation system: The liquid refrigerant in the
evaporator absorbs the heat of the air (the air is cooled and
dehumidified) and begins to evaporate, resulting in a certain
temperature difference between the final refrigerant and the air.
Liquid refrigerant It also completely evaporates into a gaseous
state, which is then inhaled and compressed by the compressor
(pressure and temperature increase). The gaseous refrigerant
absorbs heat through the condenser (air-cooled/water-cooled) and
condenses into a liquid. After throttling through the expansion
valve (or capillary tube), the refrigerant turns into a
low-temperature and low-pressure refrigerant and enters the
evaporator to complete the refrigerant circulation process.
2. the constant temperature and humidity chamber air ring system:
the fan is responsible for the air from the air inlet, air
through the evaporator (cooling, dehumidification), humidifier,
electric heater (heating) after the air outlet to the user needs
space The air sent out is mixed with the air in the space and
returned to the return air.
3. constant temperature and humidity test box electrical
automatic control system:
Including power supply and automatic control.
The power supply part through the contactor, the compressor, fan,
electric add device, humidifier, etc. supply automatic control of
the power is divided into temperature and humidity control and
fault protection part: temperature and humidity control is
through the temperature and humidity controller, Compare the
temperature and humidity of the return air with the temperature
and humidity set by the user, automatically run the compressor
(cooling, dehumidification), humidifier, electric heating
(heating) and other components to achieve automatic control of
constant temperature and humidity.
INSTALLATION
In order to facilitate heat
dissipation and maintenance of the cabinet, the place where this
equipment is installed must meet the following
conditions: **0mm from the adjacent wall or
utensils; In order to
stabilize the function and performance of the test chamber, a
place with a constant temperature of *5~*5°C and a relative
humidity of more than *5% should be
selected; the
installation site environment temperature should not be drastic
changes; should be
installed in the level of the surface (installation level
instrument to confirm the level on the
ground); should be
installed in places without direct sunlight; should be
installed in a well-ventilated place; should be
installed away from combustibles, explosives and high temperature
heat source; should be installed in dusty places;
Install it as close to the power supply as possible.
TECHNICAL
PARAMETERS
Model | *0L | **0L | **5L | **8L | **0L | ***0L |
Internal Dimensions | *0**0**0 | *0**0**0 | *0**5**0 | *0**5**0 | **0***0***0 | **0***0***0 |
External Dimensions | *0***6**4 | **0***6***4 | **0***1***7 | **0***1***7 | **0***6***7 | **0***6***7 |
Inner chamber volume | *0L | **0L | **5L | **8L | **0L | ***0L |
Temperature Range | '**0ºC***0ºC | |||||
Humidity range | *0%**8%R.H(*0%**8%R.H/5%**8%R.H is special condition) | |||||
Analytic accuracy /Evenness degree of temperature and humidity | ±0.1ºC; ±0.1%R.H/±1ºC; ±3%R.H | |||||
Precision temperature control/flactuation | ±1ºC; ±2%R.H/±0.5ºC; ±2%R.H | |||||
Heating time/cooling time | approx 4 ºC/min; approx 1 ºC | |||||
Inner and outer material | Box senior cold plate nano paint,the inner box is made of stainless steel | |||||
Insulation material | High temperature and high density chlorine containing formic acid acetic acid foam insulation material | |||||
Cooling system | Air cooled/single stage compresssor(**0ºC),wind,water cooled/double stage compressor(**0ºC***0ºC) | |||||
Security protection devices | No fuse breaker,compressor overload protection switch,refrigerant high and low voltage protection switch,high humidity over temperature protection switch,fuse,fault warning system | |||||
Accessories | View window,*0mm test,PL lamp inside the hole,partition,dry and wet bulb gauze | |||||
Controller | South Korea "TEMI""TH***0C" or"OYO"in Japanese brand ,all are optional | |||||
Compressor | The French "Taikang" brand or Bitzer Germany | |||||
Power | 1φ**0V AC ±*0% *0/*0HZ & 3φ **0V AC±*0% *0/*0HZ |
País: | China |
N º de Modelo: | Glo-m5 |
Precio FOB: | 1900 ~ 2000 / Set Obtener el precio más reciente |
Lugar de origen: | China |
Precio de pedido mínimo: | 1900 per Set |
Cantidad de pedido mínimo: | 1 Set |
Detalle de embalaje: | The wooden case |
El tiempo de entrega: | 10 days |
Capacidad de suministro: | 100 Set per Month |
Tipo de pago: | T/T, L/C, D/A, D/P, Western Union, Money Gram |
Grupo de productos : | - |