¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Phase break and phase sequence protector Phase break and phase sequence protector Phase break and phase sequence protector Phase break and phase sequence protector
Next

Phase break and phase sequence protector

25 ~ 20 / Piece ( Negotiable )

|

6 Piece Minimum Order

País:

China

N º de Modelo:

TVR-2000B

Precio FOB:

25 ~ 20 / Piece ( Negotiable ) Obtener el precio más reciente

Lugar de origen:

ningbo

Precio de pedido mínimo:

25 per Piece

Cantidad de pedido mínimo:

6 Piece

Detalle de embalaje:

Foam cartons

El tiempo de entrega:

10days

Capacidad de suministro:

6000 Piece per Year

Tipo de pago:

Other, PayPal, T/T

Grupo de productos :

-

Contactar ahora
Miembro Básico

Persona de contacto Mr. wan

Hangzhou Bay New Zone of Ningbo, Ningbo, Zhejiang

Contactar ahora

Especificaciones del producto

  • Brand Name: feinade
  • Size: 30*60*70

Descripción del producto

TVR****0B

一、Characteristics of protection

1Phase loss protection: It means that any phase occurs phase loss when the protected circuit is in running or stopping status. In this case, the red indicator light will be lighted and be priority.

2Phase opposite protection: It is a safeguard acting immediately, which protects L1, L2, and L3 three phase against wrong connection sequence. In this case, the yellow indicator light will be lighted.

3.Voltage imbalance protection: While a protection of voltage imbalance rate > 8%, the imbalance of three phase voltage will affect the safe running of the equipment. In this case that there is a phase losing, the red indicator light will be lighted and be priority.

4.Delay protection:When the fault happens, the monitor will delay 1~2 seconds to act and release.

二、Characteristics of performance

1.The protection functions of relay dont be affected by current intensity of circuit or load, impulse current, imbalance current and load characteristic. The relay could long term work under full capability and full climate. Power consumption is lower than 2W.

2There is no requirement for connecting method when it is used in protection of motor.

3This product measures up GB/T ****8.*****0、GB****8.*****1 eqv IEC******1:***9.

4The EMC of the product measures up the limits and methods of measurement of radio disturbance characteristics of GB********5.

 

三、Characteristics of working

1.If the connection of L1, L2 and L3 phases are right, the green light of the relay illuminates and the relay closes. If they are wrong, the yellow light of the relay illuminates. Exchanging any two of them, the relay will accept the phase sequence and begin to work normally. In this case that there occurs yellow light illuminated and relay unclosed after the protected equipment works normally, it should be a wrong connection of external circuit. The relay has a function of protection against wrong connection.

2.While any of these L1, L2 and L3 phases is Na phase, the red light is lighted with the unlighted green light and the released relay. While the voltage come back to normal, it will recover immediately with lighted green light and closed relay.

3.L1, L2 and L3 connect with three phase AC. NO, COM are normally open contact point and NC, COM are normally closed contact point. Use lead to connect terminal directly

País: China
N º de Modelo: TVR-2000B
Precio FOB: 25 ~ 20 / Piece ( Negotiable ) Obtener el precio más reciente
Lugar de origen: ningbo
Precio de pedido mínimo: 25 per Piece
Cantidad de pedido mínimo: 6 Piece
Detalle de embalaje: Foam cartons
El tiempo de entrega: 10days
Capacidad de suministro: 6000 Piece per Year
Tipo de pago: Other, PayPal, T/T
Grupo de productos : -

Send a direct inquiry to this supplier

A:

Mr. wan < Feynard electronics factory >

quiero saber: