¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
patient monitor CMS9000
Next

patient monitor CMS9000

|

- Minimum Order

País:

China

N º de Modelo:

CMS9000

Precio FOB:

Lugar de origen:

-

Precio de pedido mínimo:

-

Cantidad de pedido mínimo:

-

Detalle de embalaje:

-

El tiempo de entrega:

-

Capacidad de suministro:

-

Tipo de pago:

-

Grupo de productos :

-

Contactar ahora
Miembro Básico

Persona de contacto Mr. shaquil

#24 huanghe west road,E&T development Zone, Qinhuangdao, Hebei

Contactar ahora

Especificaciones del producto

Descripción del producto

Patient monitor model:CMS***0 Multi-parameter Monitor Features: 1. Color TFT Screen, waveform up to 8 channels 2. Light and portable with build-in rechargeable battery 3. UP to *0 kinds of monitor parameters 4. Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis 5. *2 hour storage and review of trend grams and tables, *0 second review of olographic Wavefo RMS. 6. Built-in recorder(option) 7. All-round monitor of adult, pediatric and neonatal. 8. Electrosurgical unit and defibrillation protected 9. Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate *0. Option parameters: EtCO2, CO, IBP, Thermal Printer ECG 1. *-lead or *-lead selectable 2. Input: *-lead: RA; LA; RL; LL; V or R; L; N; F; C 3. Lead selection: I; II; III; avR; avL; avF; Vx 4. sweep speed: *2.5mm/s, *5mm/s, *0mm/s 5. Accuracy:about 1 Bpm or 1% up and down, whichever is greater 6. Protection: Withstand ***0VAC/*0Hz voltage in isolation against electrosurgical and defibrillation 7. Calibration signal: 1mV within 5% deviation 8. Operation modes: Diagnostic, Monitor, Surgery 9. Alarm range: Adult: *****0bpm *0. Pediatric/Neonatal: *****0bpm *1. Alarm range: *2.0mV~2.0mV *2. S-T detection: YES, Arrhythmia analysis: YES *3. Alarm: YES, audible and visual alarm, alarm events recallable NIBP 1. Method: Oscillometry 2. Operation modes: Manual/Automatic/STAT 3. Measurement unit: MmHg/KPa selectable 4. Measurement types: Systolic, Diastolic, Mean 5. Measurement range: Adult: *****0mmHg 6. Over-pressure protection: YES 7. Resolution: 1mmHg 8. Accuracy: Mean error and standard deviation per ANSI/AAMI SP**0 9. Alarm: Systolic, Diastolic, Mean SpO2 1. Measurement range: ****0% 2. Accuracy:about 2% up and down (*0~**0%); 3. 0~*9% unspecified 4. Alarm range: ****0% Respiration 1. Method: RA-LL impedance 2. Pediatric/Neonatal: ****0rpm 3. Alarm range: Adult: ****0rpm 4. Pediatric/Neonatal: ****0rpm 5. Apnea alarm: YES Temperature 1. Resolution: 0.1 2. Channel: Dual-channel 3. Alarm range: ***0 Option: EtCO2 1. Measurement Mode: Side-stream or mainstream 2. Measurement range: EtCO2: ***9mmHg 3. Accuracy: CO2 concentration 4. Apnea alarm: YES CO 1. Method: Thermo-dilution 2. Measurement range: CO: 0.***0 lit. /min. IBP 1. Channel: 2 channels 2. Pressure transducer: Sensitivity: 5( mV/V/mmHg) 3. Transducer sites: ART, PA, CVP, RAP, LAP, ICP 4. Alarm range: **0~**0mmHg

País: China
N º de Modelo: CMS9000
Precio FOB: Obtener el precio más reciente
Lugar de origen: -
Precio de pedido mínimo: -
Cantidad de pedido mínimo: -
Detalle de embalaje: -
El tiempo de entrega: -
Capacidad de suministro: -
Tipo de pago: -
Grupo de productos : -

Productos relacionados contec medical systems co. of qinhuangdao

Send a direct inquiry to this supplier

A:

Mr. shaquil < contec medical systems co. of qinhuangdao >

quiero saber: