Precio FOB
Obtener el precio más reciente|
- Minimum Order
País:
Russia
N º de Modelo:
-
Precio FOB:
Lugar de origen:
-
Precio de pedido mínimo:
-
Cantidad de pedido mínimo:
-
Detalle de embalaje:
-
El tiempo de entrega:
-
Capacidad de suministro:
-
Tipo de pago:
-
Grupo de productos :
Russia
Persona de contacto Ms. Beldina
2 Melnikov Street , Yekaterinburg,
Power cables up to 3 kV with insulation and
sheathing made of PVC plastic. They are manufactured according to
TU TU 16.K01-47-200. The cables meet the requirements of GOST
31996-2012.
Cables by design, technical characteristics and
performance properties comply with NYY and NAYY brands according to
DIN VDE 0276 part 603 and DIN VDE 0276 part 627 standards of
Germany and IEC requirements 60502-1.
APPLICATION.
Cables are designed for transmission and
distribution of electric power in stationary electrical
installations for rated alternating voltage up to 0.6/1 kV with
rated frequency up to 50 Hz. Cables are designed for laying
outdoors, in the ground, indoors and in cable
ducts.
Cables are manufactured for industrial use in
supplying to the domestic market and for
export.
CONSTRUCTION.
Сonductor - round or sector-shaped, copper,
single or multi-wire 1 or 2 class according to GOST 22483.
2.
Insulation - of polyvinylchloride plasticate.
Zero core insulation (O) is blue. Insulation of grounding cores (J)
green-yellow color.
Twist - Insulated cores of three-, four-, and
five-core cables are twisted into a core around a PVC
plastic-coated or unvulcanized rubber
harness.
Filling - of unvulcanized rubber
compound.
Sheath - of polyvinyl chloride plastic
compound.
SPECIFICATIONS.
Type of climatic version of cables UHL,
placement categories 1 and 5 according to GOST
15150.
Maximum allowable core heating temperature at
short-circuit currents: (for cables with conductive cores of
cross-section more than 300 mm2) - not more than 160/140
°Ð¡.
Operating temperature range from -50
°Ð¡to 50 °Ð¡.
Relative humidity at temperature up to 35 ° C -
up to 98%.
Cables shall be laid and installed without
preheating at the temperature of -15 °C
minimum.
Permissible bending radius of cables during
laying: single-core - not less than 15 outer diameters; multi-core
- not less than 12 outer diameters.
Cables do not propagate combustion in case of
single laying.
Long-term permissible core heating temperature
during operation - not more than 70 °C.
Short circuit duration should not exceed - 4
s.
Permissible temperature of cable core heating
in overload mode - not more than 80 °C.
Maximum core heating temperature under
conditions of non-flammability in a short circuit - not more than
350 °C. Duration of operation of cables in overload mode, not more
than 8 hours a day and not more than 1000 hours for the entire
service life of cables. Construction length of cables for
cross-sections of main conductors:
- 1.5 - 16 mm2 - 450
m;
- 25 - 70 mm2 - 300 m;
- 95 mm2 and more - 200
m.
Service life - 30
years.
Warranty service life - 5 years from the date
of putting the cables into operation, but not later than 6 months
from the date of manufacture.
Storage life: in outdoor areas - not more than
2 years; under a roof - not more than 5 years; in closed rooms -
not more than 10 years.
País: | Russia |
N º de Modelo: | - |
Precio FOB: | Obtener el precio más reciente |
Lugar de origen: | - |
Precio de pedido mínimo: | - |
Cantidad de pedido mínimo: | - |
Detalle de embalaje: | - |
El tiempo de entrega: | - |
Capacidad de suministro: | - |
Tipo de pago: | - |
Grupo de productos : | Power cables for fixed installation |