¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
hospital insulation monitor equipment in surgical rooms with IEC and CE hospital insulation monitor equipment in surgical rooms with IEC and CE hospital insulation monitor equipment in surgical rooms with IEC and CE hospital insulation monitor equipment in surgical rooms with IEC and CE hospital insulation monitor equipment in surgical rooms with IEC and CE
Next

hospital insulation monitor equipment in surgical rooms with IEC and CE

1617 ~ 2310 / Piece

|

1 Piece Minimum Order

País:

China

N º de Modelo:

AIM-M100

Precio FOB:

1617 ~ 2310 / Piece Obtener el precio más reciente

Lugar de origen:

Jiangsu Province, China

Precio de pedido mínimo:

1617 per Piece

Cantidad de pedido mínimo:

1 Piece

Detalle de embalaje:

Paper carton with bubble film

El tiempo de entrega:

7-15 days

Capacidad de suministro:

50000 Piece per Year

Tipo de pago:

T/T

Grupo de productos :

Contactar ahora
Miembro Básico

Persona de contacto Ms. Jonnie

Yulv Road, Shanghai, Shanghai

Contactar ahora

Especificaciones del producto

  • Voltage:AC220V
  • Power consumption:8VA
  • Thermistor:PT100
  • Alarm value range:5~50A
  • Measuring temperature range:-50~+200
  • Alarm output:2 relay output

Descripción del producto

AIM-M100 Medical Insulation Monitor Device

Standard: IEC 60364-7-710:2002

Technical Parameter

 
AUX Power Voltage AC220V±10% Temperature monitoring Thermal resistor 2 Pt100
Power consumption ≤8VA Measuring range -50~+200℃
Insulation monitoring Resistance measuring range 10~999kΩ Alarm value range 0~+200℃
Response value 50~999kΩ Alarm
output
Output mode 2 Relays
Relative uncertainty ±10% Contact rating AC 250V/3A
DC 30V/3A
Response time ≤3s Environment Operating temperature -10~+55℃
Permissible system leakage capacitance Ce 5uF Transport temperature -25~+70℃
Measuring voltage Um ≤12V Storage temperature -25~+70℃
Measuring current Im ≤50uA Relative humidity 5%-95%,No condensation
Impedance Zi 200kΩ Altitude 2500m
InternalDC resistance Ri 240kΩ IP degree IP30
Permissible extraneous DC voltage Ufg DC280V Rated impulse voltage / pollution degree 4KV/â…¢
Load current monitoring Measuring Value 2.1~50A EMC IEC 61326-2-4
Alarm Value 5~50A Communication RS485(Modbus-RTU)
Measuring accuracy ±5%
 
 
Dimension
 
image image

Terminal Diagram
 
image

Application
image

País: China
N º de Modelo: AIM-M100
Precio FOB: 1617 ~ 2310 / Piece Obtener el precio más reciente
Lugar de origen: Jiangsu Province, China
Precio de pedido mínimo: 1617 per Piece
Cantidad de pedido mínimo: 1 Piece
Detalle de embalaje: Paper carton with bubble film
El tiempo de entrega: 7-15 days
Capacidad de suministro: 50000 Piece per Year
Tipo de pago: T/T
Grupo de productos : Medical IMD

Productos relacionados Acrel Co., Ltd.

Send a direct inquiry to this supplier

A:

Ms. Jonnie < Acrel Co., Ltd. >

quiero saber: