Descripción del producto
Brief Introduction to Product
- Scope of Application
MRD-FD type neutral ground resistor cabinet is complete equipment
specially used by generators in power plant which adopts
high-resistance grounding for neutral. The voltage grade for
generator mainly ranges from 6kv to *0kv. When one point of the
stator grounds, the devices is able to limit the grounding current
at a reasonable value and effectively restraint arc flash transient
overvoltage associated with single-phase grounding.
- Operation Environment
- Applies to indoors.
- Ambient temperature: between **0 and **0 centigrade
- The altitude shall not exceed ***0m.
- Relative humidity be or lower than *5% (*5centigrade)
- Power grid frequency: ****2Hz (*0Hz System), ****2Hz (*0Hz
System)
- The air at the installation site shall be free from chemical
corrosion, vapor or explosive dust.
- Product Model Description
According to users requirement, service of calculation resistance
value and determining model No. is free.
- Parameters of Grounding Transformer
Insulation class: H
Temperature rise:
≤**0K
Cooling: AN
Protection Level: for paper-insulated dry type grounding
transformer, the PI is divided into IP*0 (no enclosure), IP*0, and
IP*3 (with enclosure).
Insulation level, impedance voltage on-load loss and no-load loss
are according to relevant national standards.
Insulation resistance testing: high voltage-low voltage and to
earth
≥**0M
Ω, and low voltage-earth
≥**0M
Ω.
- Structure of Complete Device
- Composed Elements
Dry type single-phase grounding transformer, resistor,
disconnector, surge arrestor and so on.
CT is also equipped in the enclosure which measures neutral current
and outputs analog quantity.
- Recommended Technical Parameters of MRD-FD Type Generator
Neutral Resistor
If the parameters of project is not within above table or need more
accurate data, we could calculate according to actual project.
In the table primary side voltages of grounding transformer with
brackets are for line voltage, and the other ones are for phase
voltage. And so is the secondary side resistance.
- Diagram of Installation and Wiring
The cabinet body is made of coated cold rolled steel or
stainless steel. Wiring is led-in through wall bushing on the top
or by cable at the bottom of enclosure.
Note: The enclosure should be reliable grounding
- Ordering instructions
Please provide the following information when place the
order
Generator rated voltage, grounding transformer transformation ratio
and resistance
Grounding transformer insulation form (dry or oil-immersed)
Current transformer transformation ratio
Wiring-in from the top or bottom
Time of fault current flowing-through
Material, IP and color of enclosure and installation site
País: |
China |
N º de Modelo: |
MRD-FD
|
Precio FOB: |
10000 ~ 10000 / Set ( Negotiable ) (Negociable)
Obtener el precio más reciente
|
Lugar de origen: |
- |
Precio de pedido mínimo: |
10000 per Set |
Cantidad de pedido mínimo: |
1 Set |
Detalle de embalaje: |
wooden case |
El tiempo de entrega: |
35-45days against deposit or L/C |
Capacidad de suministro: |
30 Set per Month |
Tipo de pago: |
PayPal, Money Gram, Western Union, L/C, T/T |
Grupo de productos : |
Neutral protection devices
|