Well Used Hewlett Packard GC ***0 Plus. G***0A. SSL-Injector. FID. Autosampler.HP Compaq ***0. Software from CD.
Chromatographic Performance*
• Retention time repeatability
<0.**8% or <0.***8 min
• Area repeatability
<1%RSD
The Agilent ***0N is a state-of-theart gas chromatograph that
provides superior performance for all applications. Key to its
performance is the use of advanced electronic pneumatic control
(EPC) modules and high performance temperature control. Each EPC
unit is optimized for its intended use with a specific inlet and
detector option. Temperature control of the ***0N oven allows for
fast and precise temperature ramping. Overall thermal performance
provides optimal chromatography including peak symmetry,
retention time repeatability, and retention index accuracy. The
combination of precise pneumatic control and accurate temperature
control leads to outstanding retention time repeatability, the
basis for all chromatographic measurement.
A full array of traditional gas sampling and column switching
valves are available. A new highperformance inert pneumatic
switching manifold is available for a number of advanced
chromatographic applications (*-D heart cutting, detector
splitting, etc). Agilent GC systems are known for their
reliability, ruggedness, and long life. The Agilent **-year use
guarantee provides greater assurance for a low-cost of ownership
throughout its life.
System Capabilities
• Dual channel design supports two inlets and two detectors.
• Full range digital data output enables the smallest and largest
peaks to be quantitated in a single run.
• Full EPC is available for all inlets and detectors. Control
range and resolution are optimized for the specific inlet or
detector module.
• EPC with capillary columns provides four column flow control
modes: constant pressure, ramped pressure (3 ramps), constant
flow, or ramped flow (3 ramps). Column average linear velocity is
calculated.
• Atmospheric pressure and temperature compensation is standard,
so results do not change, even when the laboratory environment
does.
• Automatic Liquid Sampling is fully integrated into mainframe
control.
• Set point and automation control can be done from the local
keyboard or via a networked data system. Clock-time programming
can be initiated from the front panel to initiate events (on/off,
method start, etc) at a future date and time.
• A run time deviation log is created for each analysis to ensure
that all method parameters were achieved and maintained.
• Display of all GC and automatic liquid sampler (ALS) set points
at the GC or data system. Agilent supports open connectivity by
providing communication
protocols to other vendors.
Column Oven
• Dimensions: *8 × *1 × *6 cm. Accommodates up to two **5 m ×
0.**0 mm id capillary columns or two **-ft glass packed columns
(9 in coil diameter, 1/4 in od), or two **-ft stainless steel
packed columns (1/8 in od).
• Operating temperature range suitable for all columns and
chromatographic separations. Ambient temperature *4 °C to **0 °C.
- With LN2 cryo cooling:
*0 to **0 °C. - With CO2 cryo cooling: *0 to **0°C.
• Temperature set point resolution: 1 °C.
• Supports 6 oven ramps with 7 plateaus. Negative ramps are
allowed.
• Maximum achievable temperature ramp rate: **0 °C/min (**0 V
units are limited to *5 °C/min, see Table 1).
• Maximum run time: **9.*9 min (*6.7 h).
• Oven cool down (*2 °C ambient) **0 °C to *0 °C in 4.5 min).
• Ambient temperature rejection: <0.*1 °C per 1 °C.
•Support for up to 8 valves. - Valves **4, *2 V DC *3 watt in a
heated valve box - Valves **6, *4 V DC **0 mA unheated, for low
power valve appliations - Valves *8, externally powered as a
remote event from separate contact closure
• Independent heated zones, not including oven: six (two inlets,
two detectors, and two auxiliary).
• Maximum operating temperatures for auxiliary zones: **0 °C.
Electronic Pneumatics Control (EPC)
• Atmospheric pressure compensation sensor to compensate for
altitude and ambient temperature variation is standard.
• Pressure may be adjusted by increments of 0.*1 psi.
• Pressure/Flow ramps: Three maximum.
• Carrier and makeup gas settings selectable for He, H2, N2, and
argon/methane.
• Flow or pressure setpoints for each inlet or detector parameter
with both Agilent ***0N and Agilent ChemStations.
• Automated carrier has constant flow, when capillary column
dimensions are entered into the ***0.
• Split/Splitless, PTV inlets have flow sensors for the control
of split ratio.
• Inlet modules Pressure sensors: Accuracy: <±2% full scale,
Repeatability: <±0.*5 psi, Temperature coefficient : <±0.*1
psi/°C, Drift: <±0.1 psi/6 months. Flow sensors: Accuracy:
<±5% depending on carrier gas, Repeatability: <±0.*5% of
setpoint, Temperature coefficient : <±0.*0 mL/min normalized
temperature
and pressure (NTP)* per °C for He or H2; <±0.*5 mL/min
NTP per °C for N2 or Ar/CH4.
• Detector modules Accuracy: <±3 mL/min NTP or 7% of setpoint,
Repeatability: <±0.*5% of setpoint, Temperature coefficient:
<±0.*0 mL/min NTP per °C.
*NTP = *5 °C and 1 atmosphere Inlets
• Maximum of two inlets installed.
• Inlets available: - Packed purged injection port (PPIP) -
Split/Splitless capillary inlet (S/SL) - Temperature-programmable
cool on-column (PCOC) - Programmable temperature vaporizer (PTV)
- Volatiles inlet (VI) S/SL
• Suitable for all capillary columns.
• Split ratios up to ***0:1 to avoid column overload.
• Splitless mode for trace analysis. Pressure-pulsed splitless is
easily accessible for best performance.
• Maximum temperature: **0 °C.
• EPC available in two pressure ranges: ***0 psig (0 to **0 kPa)
for best control for columns 0.**0 mm diameter; ***0 psig for
columns <0.**0 mm diameter. Pressure set point resolution is
0.*1 psig. Total flow control/ sensing up to ***0 mL/min (He,
H2).
• Gas saver mode to reduce gas consumption without compromising
performance.
• Optimized septum purge flow to eliminate ghost peaks.
• Total flow setting range: 0 to **0 mL/min N2 0 to 1,**0 mL/min
H2 or He
• Flip top accessory is available for quick, easy, injector liner
changes.
• Available with manual pneumatics.