Model Number FST***0
|
**7
|
**5
|
**2
|
**7
|
**5
|
**5
|
Max. Applicable Motor Output (kW)
|
0.*5
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
Max. Applicable Motor Output (HP)
|
1.0
|
2.0
|
3.0
|
5.0
|
7.5
|
*0
|
Output rating
Â
rating
Â
Â
Â
Â
Â
Â
Â
|
Rated Output Capacity (kVA)
|
2.3
|
3.1
|
3.8
|
6.2
|
9.9
|
*3.7
|
Rated Output Current (A)
|
3.0
|
4.0
|
5.0
|
8.2
|
*3
|
*8
|
Maximun Output Voltage (V)
|
*-Phasc Proportional to voltage
|
Output Frequency (Hz)
|
0.1 ~**0Hz
|
Carrier Frequency (kHz)
|
Â
|
Â
|
*-
|
*5
|
Â
|
Â
|
Input rating
|
Rated Input Current (A)
|
*-Phasc
|
4.2
|
5.7
|
6.0
|
8.5
|
*4
|
*3
|
Rated Voltage. Frequency
|
*-Phaso **0 to **0V . *0 / *0Hz
|
Voltage Tolerance
|
± *0%(**2~**8V)
|
Frequency Tolerance
|
± 5%(*7—*3Hz)
|
Â
|
Â
|
Fan Cooled
|
Weight (Kg)
|
1.5
|
1.5
|
2.0
|
3.2
|
3.2
|
3.3
|
Control characteristics
|
| Control System
|
SPWM (Sinusoidal Pulse Width Modulation)control (V/F or
sensorless vector control)
|
Freq. Setting Resolution
|
0.1Hz
|
Output Frequency Resolution
|
0.1Hz
|
Torque Characteristics
|
Including the auto-torque, auto-slip compensation;
starting torque can be **0% at 5.0Hz
|
Overload Endurance
|
**0% of rated current for 1 minute
|
ISkip Frequency
|
Three zones, settings range 0.****0Hz
|
|Accel/Decel Time
|
0.1 to **0 seconds (2 independent settings for
Accel/Decel Time)
|
Stall Prevention Level
Frequency Setting
|
*0%***0%, Setting of Rated Current
Â
|
DC Injection Braking
|
Operation frequency ***0Hz, output ****0% rated
current
Start time **5 seconds, stop time ***5 seconds
|
Braking Torque
|
Approx. *0% (up to **5% possible with option braking
resistor or
braking unit externally mounted)
|
V/F Pattern
|
Adjustable V/F pattern
|
Operating characteristics
|
Frequency
Setting
|
Keypad
|
Set by®®
|
External
Signal
|
Potcntiometcr*5KQ/0.5W, 0 to **0VDC; 4 to *0mA, RS***5
interface;
Multi-Function Inputs 0 to 5 (7 steps. Jog, up/down)
|
Operation
Setting
Signal
|
Keypad
|
Set by RUN, STOP
|
External
Signal
|
2 wires / 3 wires (Run, Stop, Forward / Rev, ), JOG
operation,
RS***5 serialinterface (MODBUS)
|
Multi-Function Input Signal
|
Multi-step selection 0 to 7, Jog. accel/decel inhibit,
first to forth accel/decel switches, counter,
PLC operation, external Base Block (NC, NO), auxiliary
motor control is invalid, ACI/AVI
selections, drive reset. UP/DOWN key settings,
sink/source selection
|
Multi-Function Output Indication
|
AC Drive Operating, Frequency Attained, Non-zero, Base
Block, Fault Indication,
Local/Remote indication. PLC Operation indication.
Auxiliary Motor Output, Driver is Ready,
Overheat, Alarm, Emergency Stop
|
| Analog Output Signal
|
Analog frequency/current signal output.
|
|