N º de Modelo:
2TPH 1.25MPa, WNS2-1.0-Y(Q)
Precio FOB:
Lugar de origen:
China
Precio de pedido mínimo:
-
Cantidad de pedido mínimo:
-
Detalle de embalaje:
-
El tiempo de entrega:
-
Capacidad de suministro:
-
Tipo de pago:
PayPal, D/P, L/C, T/T
Grupo de productos :
Persona de contacto Ms. Sky
No.1 Zhengqian Rd, Industrial Area of Youfang Village, Yangzhong,, Zhenjiang, Jiangsu
This fire tube 2TPH 1.*5MPa boiler is fully line with the
requirements that in China, namely, safety and inspection standards
for steam boilers****6
The type of this boiler is WNS**1.*-Y(Q), which is an
automatic horizontal internal combustion oil (gas) packaged
boiler with tripart-backhaul. The first backhaul is in Wave
furnace. The secondary backhaul is in spirally corrugated tubes.
The third one is in light fire tubes. Equipped with fully
automatically control device and security protection, this boiler
could activate the Alarm that water level, emergency stop, steam
pressure, auto-starting and adjusting in combustor.
The fuel of this boiler is oil or gas. Sprayed out from the
combustor, the fuel could burn in furnace by plus pressure with
starting-fire first. The high temperature flue gas came into the
secondary backhaul, then went into the header of the flue gas in
third one, at last discharged into the air.
1. steam
capacity       Â
2 t/h
2. steam
pressure        Â
1.0 MPa
3. steam
temperature        Â
**4 ℃
4. feeding water
temperature        Â
*0 ℃
5. designing
 efficiency         Â
*8.3 ï¼…
6. designing
fuel        Â
light oil or natural gas
7. consumption of
fuel       Â
**2.6 kg/hã€**1 Nm3/h
8. area in heating
surface        Â
*5.7 m2
9. discharging gas
temperature       Â
**7.1 ℃
*0. total weight with water    ***0
kg
*1. total weight of boiler in metal   ***5.4
kg
*2. delivering weight     Â
***0 kg
*3. delivering size ***0×***0×***0 (mm)
This boiler has main parts of pressured boiler body, base,
packaging and insulation, instrumentation, valves and
accessories, front and rear flue header, electric control system
components.Boiler under the overall structure of a furnace, fire
tubes and furnace in the form of symmetrical arrangement, the
drum by the Ф***4 × *0 of the cylinder and Ф***0 × *2 groups
front and rear tube plate welded. Furnace return for the first
wave, which consists of two wave and two conical furnace welding
furnace from the waveform furnace is Ф**0 × 8. Wave furnace
structure with both increased heat transfer surface area,
increasing the rigidity of furnace, but also meet the heating
furnace after the free expansion; burn out rooms by the Ф***0 ×
*4 of the cylinder and the inner Ф***0 × *2 before, during,
after Welded tube plate group. Wet-back form, avoiding the high
temperature flue gas after the flue header on the direct erosion
and improve the reliability of the boiler; second return from the
*5 Ф*1 × 3 integral threaded pipe. Threaded pipe can be greatly
enhanced heat transfer, thus reducing the heating area, so that
the boiler compact, saving steel; third return from the *4 Ф*1
× 3 fluorescent tubes form. As the third lower return flue gas
temperature, fire tube used fluorescent tubes, compared with the
spirally pipe, has little effect on heat transfer, it can greatly
reduce the flow resistance.Front and rear the flue header with
integral flue header, cigarette box-style event off on the flue
header door, the form of overall good, beautiful, generous, easy
internal inspection and cleaning.Stack height of 8 meters
configured by the factory, the user should be approved by the
local environmental protection department of the requirements of
environmental impact report to determine the actual height, but
not less than 8 meters.
Specification of Safety valve and auxiliary
This boiler adopts two fall lift safety valves namely
A*8Y*2.5(DN*0).
This combustor is imported from abroad with neat and fully
automatic from sweeping, starting fire, fire-shifting to
emergency stop and cease-fire protection.
This feeding pump uses JGGC2.****0/*5 fully automatic pump.
In order to supervise and control water level and pressure, this
boiler has water-level instrument and water-level alarm with
pressure gage, electro connecting pressure gauge, and pressure
controller.
Main heating features
Â
NO |
 NAME |
Â
Measurement |
 Fire-box |
Fire-end box |
primary |
sencondary |
1 |
Inlet flue |
℃ |
 |
***3.2 |
***0.3 |
**6 |
ï¼’ |
Outlet flue |
℃ |
***3.2 |
***0.3 |
**6 |
**5.6 |
3 |
Flue flow rate |
m/s |
 |
 |
*2.4 |
*2 |
ï¼” |
Temperature of |
℃ |
 |
**4 |
||
5 |
area of heating |
m2 |
5 |
3.1 |
*5.2 |
*2.9 |
País: | China |
N º de Modelo: | 2TPH 1.25MPa, WNS2-1.0-Y(Q) |
Precio FOB: | Obtener el precio más reciente |
Lugar de origen: | China |
Precio de pedido mínimo: | - |
Cantidad de pedido mínimo: | - |
Detalle de embalaje: | - |
El tiempo de entrega: | - |
Capacidad de suministro: | - |
Tipo de pago: | PayPal, D/P, L/C, T/T |
Grupo de productos : | boiler |