¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial. registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Embedded LAN interface,8 channels, Industry Multipoint-Temp system (1W340C_H2)
Next

Embedded LAN interface,8 channels, Industry Multipoint-Temp system (1W340C_H2)

125.6 ~ 130.9 / Case

|

1 Case Minimum Order

País:

China

N º de Modelo:

1W340C_H2

Precio FOB:

125.6 ~ 130.9 / Case Obtener el precio más reciente

Lugar de origen:

-

Precio de pedido mínimo:

125.6 per Case

Cantidad de pedido mínimo:

1 Case

Detalle de embalaje:

-

El tiempo de entrega:

2days

Capacidad de suministro:

129 Case per Day

Tipo de pago:

T/T, PayPal

Grupo de productos :

-

Contactar ahora
Miembro Básico

Persona de contacto Ms. Alice

E area, Sixth floor,Trade Plaza One, China South City ,Pinghu Road, Longgang district,Shenzhen,Guang, Shenzhen, Guangdong

Contactar ahora

Descripción del producto

Product Information

1. Features
(1) This device supports three types probes ( Tx sensor , Dx sensor and Hx Sensor ). But, both cannot be used at the same time.
(2) Equipment can connect up to 8 probes. 
(3). Software support Windows series, and support real-time temperature display, log records, curve shows, MSN remote view data, E-mail alarm etc. Function
(4). Equipment support UDP, in which the TCP protocol, either as a server but also as a client. Server maximum can support five units (client) at the same time. UDP only support the client
(5). Equipment LAN module can be configured
(6). Equipment support reset function, when IP changes or forget the IP, you can long press "Preset keys 3 s can be restored to the default value.
(7).LAN series product can be reached WEB remote view data through the PCsensor.us     .  Welcome users to free register
 
The default LAN basic configuration
 
(1) device MAC::XX-XX-XX-XX-XX-XX
(2) device ipaddress:**2.**8.1.**8
(3) device netmask:**5.**5.**5.0
(4) device gateway:**2.**8.1.2
(5) host ipaddress:**2.**8.1.*6
(6) connection type: tcp
(7) host port:****0
(8) user name :RDing
(9) user password :*****1
(*0) firmware : 1W**0C V1.3

The following is cannot a configuration items:
As a TCP server, equipment listening port is ***0.
As a TCP client,  equipment local port is ****0.
As UDP client,  equipment local port is ****0.
2. Electronic Parameters
(1). The rated voltage: + 5 V
(2). Rated current: about **0mA
(3). Rated power: **0 mW
(4). Resolution: 0.***5 degrees Celsius  
(5). Temperature Accuracy:  Tx  sensor :+/*1.5degrees Celsius  ;
                                           Dx  sensor : ±0.5degrees Celsius 
                                           Hx sensor :  ±0.5degrees Celsius  (humidity range : <4%RH)
(6). *-Wire line length: (theory) *0 m, (suggest) < 5 m
(7). The probe number: (the biggest quantities)  8 pcs         
3. Operating Instructions
3.1 . Operation steps
 
3.1.1   First put sensors inserted to 1W**0C green interface, connect network Cable .please ensure that connect normal.
3.1.2  Turn on the power .LAN port of LINK light blink, flashing that said ACK network connection to normal. If not, please check your network is normal or not. Red LED the unusual light flashing, said equipment find probe, and reading temperature. If not, please check your probes whether good connection, you can connect well probe again after restart your device.
3.1.3  Open software, if your IP section is not our default **2.**8.1. XXX section, please manually add own IP section, (see picture ****1 and ****2)
3.*4   Add IP successful, and then open the software can find equipment if still can't find your IP that prove setting wrong or subnet mask setting wrong. When you find device, then you can modify the device's IP.
  1.    At this time, the normal work equipment, if temperature display error , that says the probe didn't insert or contact undesirable, please adjust the probe . 
3.2 Frequently Questions and resolution
1 Q: why 
Equipment connected not succeeds ?
 A: Checking Network Cable connected and Checking your LAN IP segment. If continue does not work, Please press the reset , IP restore the factory settings.
2 Q: why the device cannot find the probe?
A: whether it is operational problem?  Please ensure that all equipment with a good, then, connect the power, the device will immediately search the probe.  So, please check whether the probe is connected short circuit or poor contact. Because this is a line of communication, if there is a probe connect poor, all the other probes would happen error.
3 Q:
Why read the temperature will be *5C or ERROR ?.
A: This usually is because the probe cable is too long or the probe too much, resulting in the probe power supply shortage. Solution 1: Use low impedance of the cable and the line length should not exceed *0 meters, or probe plus extra power (*5 V). Solution 2: Ensure the interfaces reliable contact.
4 Q: Why does the device will be dead running some days later?
A: 1. this equipment should not be on the high temperature and high pressure areas. 2. Part of Probe connection has short circuit problem.

3.2   Manually add IP section
if your IP section is not our default **2.**8.1. XXX section, please manually add own IP section
 

País: China
N º de Modelo: 1W340C_H2
Precio FOB: 125.6 ~ 130.9 / Case Obtener el precio más reciente
Lugar de origen: -
Precio de pedido mínimo: 125.6 per Case
Cantidad de pedido mínimo: 1 Case
Detalle de embalaje: -
El tiempo de entrega: 2days
Capacidad de suministro: 129 Case per Day
Tipo de pago: T/T, PayPal
Grupo de productos : -

Send a direct inquiry to this supplier

A:

Ms. Alice < RDing Technology limited >

quiero saber: