ECG Simulator or called ECG signal generator
Next

ECG Simulator or called ECG signal generator

483 USD / Unit

|

1 Unit Minimum Order

País:

China

N º de Modelo:

skx-2000sup

Precio FOB:

483 USD / Unit Obtener el precio más reciente

Lugar de origen:

Xuzhou, Jiangsu, China

Precio de pedido mínimo:

483 per Unit

Cantidad de pedido mínimo:

1 Unit

Detalle de embalaje:

Packing delicate drop resistance

El tiempo de entrega:

1-2 days can be shipped

Capacidad de suministro:

100 Unit per Week

Tipo de pago:

Western Union

Contactar ahora
Miembro Básico

Persona de contacto Ms. zhouxuemei

xu zhou shi jianghaibuxiugangcheng 4haolou208, Xuzhou, Jiangsu

Contactar ahora

Especificaciones del producto

  • Xuzhou Ming Sheng Electronic Technology Co., Ltd.:Dongsheng

Descripción del producto

SKX****0SUP description The waveform type description ( using the PM***0 monitor detection ) 1, waveform code 1: normal ECG waveform The data rate of *0 BPM for *0: code The frequency range of *****0 BPM wave amplitude is fixed, is not affected by the amplitude effect 2, 2: a triangular waveform waveform code Data code for the *5 *5bpm Frequency range: *****0bpm Range 0.**4mV, the amplitude adjustment adjustment. 3, waveform code 3: Fang Bo Data code for the *0 1Hz 0.***0Hz Range 0.**4mV, the amplitude adjustment adjustment. 4, 4: sinusoidal waveform code Data code for the *0 *0Hz ****0Hz Range 0.**4mV, the amplitude adjustment adjustment. 5, the code for the 5:QRS wave waveform You can change the amplitude of T wave, QRS wave amplitude, width of QRS wave, QRS wave frequency To change the parameters through the combination of keys 6, 6: respiratory waveform waveform code Data code for *0bpm Respiratory waveform frequency adjustment range *****0 7, waveform code 7: pacing pulse signal pacing signal of positive and negative direction Data code for *0mS ( 2mS ) The frequency of *0bpm Range is *1.*4mV, the amplitude adjustment adjustment. Through the combination of positive and negative direction switch You can change the pulse width, the range of 0.**2mS 8, waveform code 8: QRS wave front pacing signals Lead pacing signal for positive and negative pulse waveform, through a combination of key switch Lead pacing signal pulse width can be adjusted, the range of 0.**2mS Range is *1.*4mV, the amplitude adjustment adjustment. 9, waveform code 9: adjust the waveform amplitude Data code for the **0 1Mv **0 4Mv *0, waveform code for A: Data code for the 1 *5bpm normal Data code for the 2 **0bpm heartbeat tachycardia Data code for the **5 BPM heartbeat bradycardia Data code for the ***0 BPM T supraventricular heartbeat tachycardia Data code **0 ( *3 ) BPM drain Bo Data code for the **4 BPM agonal rhythm Data code for the *0 BPM arrest *1, the code for the B: Data code for the 1 *5bpm normal Data code for the 2 *2bpm NSR with PAC Data code for the 3 *2bpm rough type of atrial fibrillation, irregular heartbeat 4 *0bpm room early data code 5 *0bpm 2 consecutive ventricular premature data code ( 2 ventricular extrasystole) 6 *0bpm 3 consecutive ventricular premature data code ( multiple ventricular premature ) 7 *0bpm 4 consecutive ventricular premature data code ( multiple ventricular premature ) Data code for the 8 *0bpm premature beats Data code for the 9 *0bpm 2 consecutive beats Data code for the *0 *0bpm 4 consecutive beats s Data code for the *1 *0bpm 1 beats, a normal waveform Data code for the *2 *0bpm all PVCs ( VF / VT ) *2, waveform code for C: Data code for the 1 *0bpm degree block Data code for the 2 *5bpm degree block *5 BPM Data code for the 3 *1bpm degree block *1 BPM Data code for the 4 *0bpm L bnd1 branch block Data code for the 5 *0bpm R bnd1 branch block *3, waveform code for D: Data code 1 ( ****3 ) BPM ATRIAL PAC Data code for the 2 *0bpm pvc1 early Lv focus Data code for the 3 *0bpm pvc1 early Rv focus Data code for the 4 *0bpm nodal PNC Data code for the 5 *0bpm two premature ventricular bigeminy Data code for the 6 *0bpm premature ventricular trigeminy Data code for the 7 *0bpm R ON T

País: China
N º de Modelo: skx-2000sup
Precio FOB: 483 / Unit Obtener el precio más reciente
Lugar de origen: Xuzhou, Jiangsu, China
Precio de pedido mínimo: 483 per Unit
Cantidad de pedido mínimo: 1 Unit
Detalle de embalaje: Packing delicate drop resistance
El tiempo de entrega: 1-2 days can be shipped
Capacidad de suministro: 100 Unit per Week
Tipo de pago: Western Union
Grupo de productos : ECG monitoring equipment category