Descripción del producto
Purpose of the
Product
Troponin I/Myoglobin/CK-MB Test
kit (Colloidal Gold) detects the amount of Cardiac Troponin I,
Myoglobin, and CK-MB consists in human blood
qualitatively. Positive cTnI normally can be found in
early myocardial
infarction. The minimum detectable amount of RF of
the product is *0ng/ ml.
Product name
Common name: Cardiac Troponin
I/Myoglobin/CK-MB Test Kit (Colloidal Gold)
Name of commodity: Cardiac
Troponin I/Myoglobin/CK-MB Test Kit
English name:Cardiac Troponin I/Myoglobin/CK-MB Test Kit
(Colloidal Gold)
Principle
Cardiac Troponin I Test Kit
(Colloidal Gold) is using colloidal gold immune chromatography
principle, and the cTnI, MYO, CK-MB conjugates with the colloidal
gold markers respectively, then the conjugate specific binding
with cTnI, MYO, CK-MB antibody on the test strip to emerge the
test line (T line). The dissociative colloidal gold marker
move to the control area to combine with corresponding antibody
displays control line (C line).
Structure
Composition
Troponin I/Myoglobin/CK-MB Test
kit (Colloidal Gold) is composited byPVC panel, suck sample paper, and
test strip. Thetest strip
mainly has colloidal gold marker and cTnI antibody, MYO antibody,
and CK-MB antibody on it.
Sampling
Sampling test subjects venous
blood 1ml or **3 drops from the finger tip, serum or whole blood
obtained after centrifugation
Add anticoagulant to prevent the coagulum
of the sample, and finished the test immediately after sample
collection.
The Sample
could be stored in **8 Celsius degree storage for 3 days.
Test
Place the test board on a flat
table.
Hold the straw vertically to
insure the sample free drops into the sampling hole.
Add 3 drops of the patient's serum
or plasma on the test paper first; add 1 more drop if the liquid
do not appear in *0 seconds.
Read the results
Read the result in *0 minute to *5
minutes after the test, the result is invalid after *0
minutes.
The Interpretation of Test
Results
Positive:
There are four colored lines
appears on the test strip, and three of them locates in T1
(CtnI), T2 (MYO), and T3(CK-MB) respectively. The other line
is C line. The quicker the T line appears and the darker the
color is, the higher amount of corresponding indexes in the
sample. If there is one or more than one line in T area
appears with C line indicates that the corresponding index is
positive.
Negative:
Only C line appears when the
result is negative.
Invalid:The test is invalid when C line does not
appear. Take a second test.
Reference Value
If the result of the test is
positive, the concentration of cTnI≥2ng/ml,
MYO≥*0ng/ml, and CK-MB≥5ng/ml.
Explanation of the Reading
Result
cTnI: When myocardium is injured,
cTnI releases into blood. **6 hours after the injury, the
amount of cTnI starts to increase. The peak occurs in *4 to
*0 hours, and it recovers in 5 to 7 days. cTnI has high
cardiacspecificity
and sensitivity, it has
been recognized as the most specific cardiac marker.
MYO: When myocardium cell is
injured, MYO releases rapidly into the blood, and it increases in
*0 minutes to 2 hours after acute myocardio infarction
occurs. The peak occurs in 5 to *2 hours, and it recovers *8
to *0 hours. MYO does not has cardiac specificity, but it is
more sensitive than the other markers after the
infarction. Hence MYO is a potential early
marker.
CK-MB: A isozyme of CK, and it is
mainly exist in myocardium. CK-MB has higher sensitivity
than CK and the positive detection rate is **0%. CK-MB index
increases in 3 to 8 hours after the infarction and reaches the
peak in 9 to *0 hours.
Limitations
This product only provides
qualitative result of cTnI, MYO, and CK-MB in blood; please use a
quantitative reader by our company if a quantitative result is
needed.
The test result of the product
cannot be used as the sole criterion, and it is only a doctors’
or patients’ reference with comprehensive judgment.
Negative result could not
eliminate the probability of myocardium injury because the amount
of cardiac marker increases after specific time period of the
injury.
Cautions
1. This product is only used for
in vitro diagnosis
2. This product only provides
qualitative result of cTnI in blood; please use a quantitative
reader by our company if a quantitative result is needed.
3. Read the instructions and check
the expiry date on the aluminum bag carefully before use, stop
using the product if the aluminum bag is damaged.
4. Use it properly.
Storage and Expiry
Period
Packed cardiac troponin I test kit
(colloidal gold) should be stored in a space which has
relative humidity less than
*0% and cooler than *0 Celsius degrees.
Expiry Period: *4 months
Packaging
Specifications
*0 Kits/box
Executive
standard:YZB/ E
********2
Registration Certificate of
Medical Device (RCMD):E
RCMD ***9 ******3
País: |
China |
N º de Modelo: |
JH-0103
|
Precio FOB: |
0.5 ~ 1.5 / Piece (Negociable)
Obtener el precio más reciente
|
Lugar de origen: |
Hubei,China |
Precio de pedido mínimo: |
0.5 per Piece |
Cantidad de pedido mínimo: |
1000 Piece |
Detalle de embalaje: |
30 Kits/box, 20 Boxes/ctn, 8kg/ctn |
El tiempo de entrega: |
Around two weeks |
Capacidad de suministro: |
1000000 Piece per Week |
Tipo de pago: |
T/T, L/C |
Grupo de productos : |
Cardiac Marker Test Series
|