Descripción del producto
1. Range:
This
acknowledgement stipulates the requirements, test methods and
inspection routines.
This acknowledgement
applicable for Anion Generator made by this
company.
2. Requirements
:
2.1Main
performance of Anion Generators
2.1.1
Function: produce high-voltage emitting negative
ions.
2.1.2
Materials of outer covering: use fireless material that
resists heat.
2.1.3
Output wire:
a) Power
line: by UL***0 *4 # **5°C **0V red, black
wire;
b) High-voltage:
UL***9 *4AWG 6KVDC **5°C,white
high-voltage wires.
2.2Outer
appearance: It should be fine. Outer plastic and its wire is in
good order without cuts, scratches, deforming, or cracking. The
surface of epoxy resin is fkat. The inner parts can’t be exposed
outside the surface. The screw-holes cannot be stopped up. The
label is clean and seeable.
2.3 Structure and
Dimension: meet design requirement.
2.4 Working
Condition:
2.4.1
Rated power/ voltage: ******0V
*0/*0Hz.
2.4.2
Working temperature range: **0°C
***-**0°C.
2.4.3
Storage temperature range: **0°C
**-**0°C.
2.5 Electrical
Features: The general test temperature is *5°C
±5°C;
The relative humidity is *0%±*0%.
2.5.1Consumed
power: ≤1W.
2.5.2
Output Voltage: **0V test
voltage:
a. Output voltage:
Output negative voltage 2.5KV ~ 4.0KV
b. Negative ion concentrations were greater than 1.0
× **6n/cm3
2.5.3
Ozone density (concentration):
≤0.*5ppm.
2.5.4
Insulating features:
a.) Insulation
resistors between and output ≥ *5MΩ;
b.) Insulating resistors between terminal and outer
covering ≥**0MΩ.
2.5.5
Electrical Intensity:
a.) Between
terminal and output terminal, ***0V *0Hz 1s non-puncture, earth
leakage ≤0.5mA
b.) Between
terminal and outer covering, ***0V *0Hz 1min non-puncture, earth
leakage ≤0.5mA
2.6 Mechanical
performance: The pulling force of output line bears *0N within 5
seconds without any breaking, displacement, or rupture of outer
covering, etc.
2.7 Environmental
Requirements:
2.7.1.
Heat-resistant:
a.) should accord with the stipulations of article No 2.5.1,
2.5.2, 2.5.3, 2.5.4, 2.5.5 after testing.
b.) Outer covering
and other parts should not be obviously
deformed.
2.7.2
Cold-resistant:
a.) Should accord with
the stipulations of article No2.5.1, 2.5.2, 2.5.3, 2.5.4, 2.5.5
after testing.
b.) Outer covering
and other parts should not be obviously
deformed.
3. Testing
Methods:
3.1. Appearance:
estimated by visual range.
3.2 Structure and
dimension: measured by surveying instruments conforming to the
standard.
3.3 Consumed
power: measure the electric current at
rated-working-voltage by equivalent circuit,
I≤4mA
3.4Output voltage:
rated voltage of high voltage table with ***0MΩ resistance test
output voltage.
3.5 Negative ion
concentration: The standard atmospheric concentration tester for
testing. Instrument to warm up *5 minutes after the test,
negative ion concentration from the output port to receive the
same level Test Center at *0cm distance, interference from
outside factors and circumstances, normal ****5 seconds after the
measured ion concentrations.
3.6 (Ozone density
concentration): put to the test in a closed room (room space 2.5m
x3.5m x3.0m). Anion Generator is on (set up an electric circuit)
at rated voltage for *4 hours. Anion probe is put up in *0mm away
from the outlet mouth where air flows. We measure the ozone
density.
3.7 Insulating
features: Make a test with apparatus of insulating
resistance. Use **0Vd.c.Measure
insulating resistance between terminal and output terminal,
terminal and outer covering.
3.8 Electrical
Intensity: By pressure-tight test, the leakage of electricity is
0.5mA.
a.) In ***0V *0Hz
voltage between terminal and output terminal, no puncture
by pressure –tight test for 1 second.
b.) In ***0V *0Hz
voltage between terminal and outer covering, no puncture by
pressure –tight test for 1 minute.
3.9 Mechanical
performance: The pull test is made fort leg wore with a weight
(scale).
3.*0
Heat-resistant: When the electric line is cut off and the
temperature is **0°C, we put it in the room for *4 hours .We test
it when the room temperature returns to
normal.
3.*1.
Cold-resistant: When the electric line is cut off and the
temperature is **0°C, we put it in the room for *4 hours. We test
it when the room temperature returns to
normal.
4. Inspection
routine:
4.1 All the Anion
Generators must be inspected and qualified by our inspectors
before leaving the factory.
4.2 Ex-factory
inspection items should be made as per Formula
1.
All the formal inspection items should be made in accordance with
the stipulations prescribed by the
“Acknowledgement”
4.3. The Quality
Control Department draws samples for inspection from all the
qualified products before they leave the factory. Only when they
are qualified, can the batch of products be put in storage and
delivered to the customers.
Sampling
checking method is made according to GB***8.*****3 .We draw samples
once normally (refer to Formula 1.)
País: |
China |
N º de Modelo: |
HB-213
|
Precio FOB: |
0.7 ~ 0.75 / Piece ( Negotiable ) (Negociable)
Obtener el precio más reciente
|
Lugar de origen: |
Zhenjiang ,China |
Precio de pedido mínimo: |
0.7 per Piece |
Cantidad de pedido mínimo: |
10000 Piece |
Detalle de embalaje: |
Cartons |
El tiempo de entrega: |
20-40days |
Capacidad de suministro: |
50000 Piece per Day |
Tipo de pago: |
Other |
Grupo de productos : |
- |