¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC
Next

Acrel AIM-M100 hospital insulation monitor in surgical rooms with IEC

1617 ~ 2310 / Piece

|

1 Piece Minimum Order

País:

China

N º de Modelo:

AIM-M100

Precio FOB:

1617 ~ 2310 / Piece Obtener el precio más reciente

Lugar de origen:

Jiangsu Province, China

Precio de pedido mínimo:

1617 per Piece

Cantidad de pedido mínimo:

1 Piece

Detalle de embalaje:

Paper carton with bubble film

El tiempo de entrega:

7-15 days

Capacidad de suministro:

50000 Piece per Year

Tipo de pago:

T/T

Grupo de productos :

Contactar ahora
Miembro Básico

Persona de contacto Ms. Jonnie

Yulv Road, Shanghai, Shanghai

Contactar ahora

Especificaciones del producto

  • Voltage:AC220V
  • Power consumption:8VA
  • Thermistor:PT100
  • Alarm value range:5~50A
  • Measuring temperature range:-50~+200
  • Alarm output:2 relay output

Descripción del producto

AIM-M100 Medical Insulation Monitor Device

Technical Parameter

 
AUX Power Voltage AC220V±10% Temperature monitoring Thermal resistor 2 Pt100
Power consumption ≤8VA Measuring range -50~+200℃
Insulation monitoring Resistance measuring range 10~999kΩ Alarm value range 0~+200℃
Response value 50~999kΩ Alarm
output
Output mode 2 Relays
Relative uncertainty ±10% Contact rating AC 250V/3A
DC 30V/3A
Response time ≤3s Environment Operating temperature -10~+55℃
Permissible system leakage capacitance Ce 5uF Transport temperature -25~+70℃
Measuring voltage Um ≤12V Storage temperature -25~+70℃
Measuring current Im ≤50uA Relative humidity 5%-95%,No condensation
Impedance Zi 200kΩ Altitude 2500m
InternalDC resistance Ri 240kΩ IP degree IP30
Permissible extraneous DC voltage Ufg DC280V Rated impulse voltage / pollution degree 4KV/â…¢
Load current monitoring Measuring Value 2.1~50A EMC IEC 61326-2-4
Alarm Value 5~50A Communication RS485(Modbus-RTU)
Measuring accuracy ±5%
 
 
Dimension
 
image image

Terminal Diagram
 
image

Application
image

País: China
N º de Modelo: AIM-M100
Precio FOB: 1617 ~ 2310 / Piece Obtener el precio más reciente
Lugar de origen: Jiangsu Province, China
Precio de pedido mínimo: 1617 per Piece
Cantidad de pedido mínimo: 1 Piece
Detalle de embalaje: Paper carton with bubble film
El tiempo de entrega: 7-15 days
Capacidad de suministro: 50000 Piece per Year
Tipo de pago: T/T
Grupo de productos : Medical IMD

Productos relacionados Acrel Co., Ltd.

Send a direct inquiry to this supplier

A:

Ms. Jonnie < Acrel Co., Ltd. >

quiero saber: