Precio FOB
Obtener el precio más reciente220000 ~ 22540 USD / Set
|1 Set Minimum Order
País:
China
N º de Modelo:
RT5000kWLB
Precio FOB:
220000 ~ 22540 USD / Set Obtener el precio más reciente
Lugar de origen:
China
Precio de pedido mínimo:
220000 per Set
Cantidad de pedido mínimo:
1 Set
Detalle de embalaje:
Wrapping film
El tiempo de entrega:
25-30 days
Capacidad de suministro:
1 Set per Month
Tipo de pago:
L/C, T/T
Grupo de productos :
Persona de contacto Mr. Winston
East Section of Hongyu Road, Jinshan Industrial Park, Luojiang District, Deyang City, Sichuan Provin, Deyang, Sichuan
3kW~****0kW Air Cooled AC 3 Phase Resistive Load Bank for
Generator UPS Power Plant Load Testing
Certificates:
ISO***1/ISO****1/ISO****1/CE/SGS
Product: Resistive load
bank
Application:
Generator,UPS,transformer,genset load test
Load type: resistive
Capacity: 3kW~****0kW
Voltage:3 Phase 4
wire,AC**0V/AC**5V/AC**0V/AC**0V/AC6.3kV/AC*0.5kV/Customized
Frequency: *0Hz/*0Hz
Power factor: 1.0
Load accuracy: ±3%
3Phase Balance: Unbalance: ≤3%
Insulation:
F
Power source connection: copper
bar+terminal
Time rating:
continuous design/temporary
Temperature:
**0℃ to
*0℃
Humidity:
up
to **0%
Altitude:
up
to ***0m
Atmospheric pressure:
*6
to **6kPa
â– CONTROL
MODE:
Two options for
selection
1, Local panel manual control: The load bank
is equipped with a local control panel and is divided into several
power steps, which can be loaded through switch
control.
2, Manual + PCcontrol:
control the load through the data management
softwarein the
computer,realize
all test functions,display,record
and manage test data,generate
various curves,charts
and test reports and
support printing.
There is Manual/Automatic switch,and when
you use PC to operate,the manual can not operate and vice
versa.
3,PC control
system:
1,Computer:
I5 processing system.
2,Network
cable: *0m category 6 network cable.
3,Software
control system.
4,Communication
interface:RJ*5.
5,Support
printing.Table saved by EXCELL,curve saved by
word.
6,Software
language: English
â– USE
ENVIRONMENT
Two options for
selection
1,Indoor(IP*0)
2, Outdoor(IP*4),With
canopy.
â– RESISTIVE
LOAD
Min.step:
Nominal1kw
resolution or customized
Steps: According to
the CAPACITY of load bank.
â– COOLING
SYSTEM
1,Cooling
mode: Forced ventilation,horizontal air
inlet,horizontal/verticaloutlet
2,Airflow/Fan power and air volume shall be
designed according to 2 times surplus coefficient of heat loss.
3,Brand:first-line well-known brand at domestic and
abroad
4,Power
supply mode:
3phase AC power supply.
5,Noise:≤65db
(3M)
6,The fan
adopts axial flow fan, aviation aluminum fan blade, decentralized
air supply design, sufficient air volume, low noise, high strength,
corrosion resistance, durability and other advantages of the fan
blade .
â– LOAD
TEST FUNCTION
1,Real time
display of current
2, Voltage
3, Frequency
4, Power
5, Power
factor
6, Electrical
performance indicators
7, Curve and
report output
8, System
electrical parameter monitoring
9, Automatic
data acquisition
*0,Sampling
accuracy:
Voltage: ±0.5%; Current: ±0.5%; Frequency:
±0.1%; Power: ±1%; Power factor: ±1%
â– LOAD
PROTECTION/FUNCTION
1,Low air
volume: when the air volume of any fan is insufficient, it will
automatically unload and alarm.
2,High
temperature: automatically unload and alarm when the load
temperature exceeds the safety threshold.
3,Over
voltage: it will automatically unload and alarm when the load
voltage exceeds the safety threshold.
4,Fan
interlock protection: the load cannot be loaded before the fan
power switch is turned on.
5,Short
circuit/over current: the load circuit is equipped with a fuse to
avoid damage to the equipment in case of load short circuit or
excessive current.
6,Emergency
stop: manual one forced unloading is available, and it
cannot be loaded under emergency stop locking
status.
7,Fan phase
sequence automatic transfer protection: when the control power line
is not connected according to the correct phase sequence, the
three-phase fan can also operate in the normal
direction.
8,Protection switch: some protection functions
are equipped with switches, and corresponding protection functions
can be temporarily turned off in case of false alarm or special
needs.
9,Grounding
protection: in order to avoid electrification of the chassis and
electric shock hazard, the load cabinet is equipped with special
grounding protection terminals.
*0,Operational indicator: indicates whether the
device can be put into load, and the indicator light on indicates
that the device is in normal state and can be put into
load.
*1,Fan
operation indicator: indicates whether the fan of the device is
running, and the corresponding indicator light for fan startup is
on.
*2,Load
switch: the control device is to switch on or off the load, and jog
the switch to switch on the selected load.
â– CABINET/ENCLOSURE
1,Color:RAL***5,or made by customer
suppliedcolor
number.
2, Material: Q**5 cold
rolled steel plate.
3,Painting:
The exterior is sprayed with special paint for ships, which is
resistant to salt spray, acid and alkali, and seawater erosion. The
interior is sprayed with high-temperature resistant paint, and the
internal support is hot-dip galvanized.
4,Layout
design: the layout is symmetrical, and the control room is at the
front of the container. The load is located on both sides of the
container. Convenient for later cleaning and
maintenance.
5,Container
typeenclosure/cabinetstandards
GB/T ********8 -Series 1
Container Classification, Dimensions and Rated
Mass
GB/T *********6 -Container
Door Frame Sealing Strip
GB/T ********6 -Series 1
Container Corner Pieces
GB/T *********3 -Corrosion-resistant Steel Plates and Strips
for Containers
GB/T *********4 -Plywood
for Container Floor
GB/T *********5-Marine
Container Supports
GB/T ********2 Series 1
Containers -
Technical Requirements and Test Methods - Part 1: General Purpose
Containers
â– MOVEMENT
OPTIONS
1, 4 Lifting holesat the
top four corners of the load bank.
2, 4Castors at
the bottom four corners of the load bank.
3, 2Forklift
holes at the bottom middle of the load
bank.
â– PACKING
Wrapping film
â– MAIN
PARTS BRANDS
Contactor/Circuit
breaker/Fuse:ABB/Schneider/DELIXI brand
â– SPARE
PARTS
Standard configuration
â– FACTORY
TEST/ONSITE ACCEPTANCE
1,
we will test the load bank **0% before delivery.
2,Two options
for selection
â–
Remote operate the load bank by software like QQ,Sunflower or
others(free).
â–
Send technician to the site(Not
free)
Contact us
for details for different CAPACITY load
bank.
País: | China |
N º de Modelo: | RT5000kWLB |
Precio FOB: | 220000 ~ 22540 / Set Obtener el precio más reciente |
Lugar de origen: | China |
Precio de pedido mínimo: | 220000 per Set |
Cantidad de pedido mínimo: | 1 Set |
Detalle de embalaje: | Wrapping film |
El tiempo de entrega: | 25-30 days |
Capacidad de suministro: | 1 Set per Month |
Tipo de pago: | L/C, T/T |
Grupo de productos : | Resistive Load Bank |