Precio FOB
Obtener el precio más reciente( Negotiable )
|1 Piece Minimum Order
País:
China
N º de Modelo:
194L-ASY
Precio FOB:
( Negotiable )Obtener el precio más reciente
Lugar de origen:
-
Precio de pedido mínimo:
-
Cantidad de pedido mínimo:
1 Piece
Detalle de embalaje:
BOX
El tiempo de entrega:
-
Capacidad de suministro:
1000 Piece per Week
Tipo de pago:
-
Grupo de productos :
-
Persona de contacto amy
Chongqing, Chongqing
BJ***4L series is to measure network parameters and the development
of special electronic measuring instruments, parameter measurements
are displayed on the monitor 5 groups, can simultaneously measure
and manage over *0 network parameters. Supply line voltage, phase
voltage, phase current, phase power factor, total current, active
power, reactive power, apparent power, active power, reactive power
and other network parameters; while providing phase current, total
current, total power power, reactive power and apparent power
demand value, all network parameters are a value, BJ***4L has a **5
communication interface, adjustable voltage, current transformer
ratio and a variety of voltage mode so that it can adapt a
variety of different voltage specifications of electricity
occasions.
Features:
1, real-time display
Real-time display of three-phase power
factor, phase active power, phase reactive power, three-phase
voltage, phase current, active power, reactive power and so on.
2, the basic power parameter acquisition
The basic power parameters acquisition
module: real-time acquisition of voltage and current signals and
calculates the three-phase power factor, phase active power,
reactive power three-phase, three-phase voltage rms, rms phase
current, active power, reactive power Wait.
3, the communication function
Communication module has two supply the
user with a choice of Freedom: 1, RS**5 / RS**2 2, USB utilize
communication module with the host computer (PC or PLC) for wired
or wireless communications, the use of background software can
achieve preset parameters, real-time data collection grid and other
functions.
4, parameter presets
Preset parameters can be done in two
ways: 1, the use of simple keyboard provided by the meter; 2,
use PC analysis software and instrument communication .
5, communication protocol
MODBUS RTU protocol, communication
protocol can be customized such as: MODBUS ASCII, etc.
País: | China |
N º de Modelo: | 194L-ASY |
Precio FOB: | ( Negotiable ) Obtener el precio más reciente |
Lugar de origen: | - |
Precio de pedido mínimo: | - |
Cantidad de pedido mínimo: | 1 Piece |
Detalle de embalaje: | BOX |
El tiempo de entrega: | - |
Capacidad de suministro: | 1000 Piece per Week |
Tipo de pago: | - |
Grupo de productos : | - |