Precio FOB
Obtener el precio más reciente9000 / Pack
|1 Box Minimum Order
País:
China
N º de Modelo:
CHKZ4
Precio FOB:
9000 / Pack Obtener el precio más reciente
Lugar de origen:
CHINA
Precio de pedido mínimo:
9000 per Pack
Cantidad de pedido mínimo:
1 Box
Detalle de embalaje:
WORDEN
El tiempo de entrega:
95DAYS AFTER ORDER
Capacidad de suministro:
10000 Piece
Tipo de pago:
T/T, L/C, D/A
Grupo de productos :
Persona de contacto Mr. Taili
Meichi Industrial Zone, yunlong Town, Ningbo, Zhejiang
No. | Item | Unit | Data for ZW32-12KV | Data for ZW32-15KV | |||||
1 | Rated Voltage | KV | 12 | 15 | |||||
2 |
Rated insulation level (phase to ground, phase to phase) |
1 min Frequency withstand voltage | Dry | KV | 42 | 50 | |||
Wet | 34 | 45 | |||||||
Lighting Impulse Withstand Voltage(Peak) | KV | 75 | 110 | ||||||
3 | Medium Interruption: | Vacuum | |||||||
4 | Medium isolation: | Solid polymer | |||||||
5 | Mechanism of operation (closing and shot): | Magnetic | |||||||
6 | Assembly: | Suitable weather for substation | |||||||
7 | Environmental operating temperature: | FROM -40℃-+50℃ | |||||||
8 | Position indicator: Green-closed; Open-red | ||||||||
9 | Minimum distance of contouring of the insulation | MM | 400 | 600 | |||||
10 | Rated Frequency | Hz | 50/60 | ||||||
11 | Rated Current | A | 630/800/1250 | ||||||
12 | Rated Min Start-up Current | Numerical | A | adjustable | |||||
Permissible deviation | % | ±10 | |||||||
13 | Rated Fault Interrupter Capacity | KA/3s | 12.5/20 | ||||||
14 | Rated Fault Symmetrical Making Current | KA | 12.5/20 | ||||||
15 | Rated Short-Time Withstand Current | KA | 12.5/20 | ||||||
16 | Rated Peak Withstand Current | KA | 12.5/20 | ||||||
17 | Interrupting Time(Max) (Cycle) | s | No more than 4 | ||||||
18 | The conditions of different phase earthed fault short-circuit breaking current | KA | 17.3 | ||||||
19 | Rated Cable Charging Breaking current | A | 25 | ||||||
20 | Rated Operating Sequence | O-0.1s-CO-2s-CO-2s-CO-C | |||||||
21 | Rated Operation Voltage | V | AC/DC110/125/220/240 | ||||||
22 | Rated Short-Circuit Current Breaking Times | Time | |||||||
90%~100% Rated Short-Circuit Current volume | 16 | ||||||||
45%~55% Rated Short-Circuit Current volume | 44 | ||||||||
15%~20% Rated Short-Circuit Current volume | 56 | ||||||||
23 | Mechanical Life (Mechanical stability) | Time/Unit Operation | 15000 | ||||||
24 | Current Transformer | Primary Rated Current | A | 200/400/600/1000 | |||||
Secondary Rated Current | 1A or 5A | ||||||||
Accuracy Class | CL | 0.2/5P20 | |||||||
Capacity | VA | 2VA TO 15VA | |||||||
Installation | Built in /In bushing | ||||||||
25 | Capacitor Voltage Transformer | Primary Rated Voltage | KV | 12/√3/15/√3 | |||||
Secondary Rated Voltage | V | 0.4-7 | |||||||
Accuracy Class | % | 1% | |||||||
Installation | Outdoor/In busing | ||||||||
26 | Special Manual Closing Mechanism |
|
optional | ||||||
27 | Earthing | Solidly Earthed | |||||||
No. |
Item | Unit | Data for ZW32-27KV | Data for ZW32-38KV | ||||
1 | Rated Voltage | KV | 27 | 38 | ||||
2 | Rated insulation level (phase to ground, phase to phase) | 1 min Frequency withstand voltage | Dry | KV | 65 | 95 | ||
Wet | 50 | 80 | ||||||
Lighting Impulse Withstand Voltage(Peak) | KV | 145/150 | 185 | |||||
3 | Medium Interruption: | Vacuum | ||||||
4 | Medium isolation: | Solid polymer | ||||||
5 | Mechanism of operation (closing and shot): | Magnetic | ||||||
6 | Assembly: | Suitableoutdoorfor substationor pole mounted | ||||||
7 | Environmental operating temperature: | FROM -40℃-+50℃ | ||||||
8 |
País: | China |
N º de Modelo: | CHKZ4 |
Precio FOB: | 9000 / Pack Obtener el precio más reciente |
Lugar de origen: | CHINA |
Precio de pedido mínimo: | 9000 per Pack |
Cantidad de pedido mínimo: | 1 Box |
Detalle de embalaje: | WORDEN |
El tiempo de entrega: | 95DAYS AFTER ORDER |
Capacidad de suministro: | 10000 Piece |
Tipo de pago: | T/T, L/C, D/A |
Grupo de productos : | 33KV-245KV Power Substation |