¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
nurse call system
Next

nurse call system

|

1 Minimum Order

País:

China

N º de Modelo:

CS800

Precio FOB:

Lugar de origen:

-

Precio de pedido mínimo:

-

Cantidad de pedido mínimo:

1

Detalle de embalaje:

carton box

El tiempo de entrega:

15 days against firm order

Capacidad de suministro:

10000

Tipo de pago:

-

Grupo de productos :

-

Contactar ahora
Miembro Básico

Persona de contacto Mr. Ken

Building 3, No.2568 GuDai Road, Shanghai, 201100, China, Shanghai, Shanghai

Contactar ahora

Especificaciones del producto

Descripción del producto

2,Functional Features

  1. Basic Function:
  2. The master station can call any calling and the calling can also call the  master machine, two way speaking also available.
  3. Capacity: Each master machine can control up to *6 user station.
  4. User station:There is two types of user station, user station(normally, can two way speaking), waterproof urgent ( bath room use, it not have speak function and only have the function of calling.)
  5. Calling number change: The number of user station can be set from master station when the power is on, it is not necessary to change the chip.
  6. Subsidiary display for nurse station:Since standard nurse station is desk type, if customer need the nurse station installed on the wall, we can provide a subsidiary display for nurse station. This subsidiary display panel can display the calling information with master station simultaneously.
  7. Calling level: Every user station can be set from nurse station as special, urgent, normal. The response grade of the three level is different, urgent is most priority, special is second priority, normal is the lowest level.
  8. Alarm light:Each master station can control *8 units alarm light. Each alarm light can control *6 user stations.
  9. Display panel: One unit master station can connect several units display panel. When the quantity of display panel is less than 2 units, extra power supply is not necessary and it can powered directly by master station.
  10. Information display: When there is calling happen, master station and display panel display the numbers of  bed  ( 2 digit), when there is no calling happen, display current time (4 digit)
  11. Two way speaking: the system have the function of two direction speaking, that means user station can ask talk with master station, or the master station can dial the Number of beds to talk with the user station. The voice is very clear no noise.
  12. Multi-units display:when there is many calling happen at the same time, the master station will display the number of current speak user station, if not speak, the muster station will keep display every calling number take turns every 2 seconds, also it makes sound.
  13. Calling Memory: if the calling is not answered from nurse, the information will be saved in the master station and keep display until replacement.
  14. Function Set: all the functions can be set from the telephone machine.
  15. Music/Volume: It has four different type music for optional, Volume adjustable.
  16. Wire connect method: between master station and user station, it adopts 2 core wireconnect. Between nurse station and display panel, it adopts 3 piece wire connect
  17. Master station network : it has computer manage function, one unit signal collector ( with one computer) can most control *9units master station.
  18. Computer management: All the information of calling, replacement, speak can be saved in the computer database. The connect outlet of system is RS**2 or USB outlet.
  19. Wireless Equipment:It can connect with wireless pager system and short message sending machine. It enables to send the calling information to appointed pager or mobile phone.
  20. Self-test:The system has self-testing function, which can both detect and show detailed mistake code of system break down.
  21. Communication distance: The maximum communication distance can up to **0 meters.The distance of master station with display panel can up to **0 meters.
  22. Broadcast function: The system support system broadcast function, that is it can be broadcast from master station to all the user stations or appointed groups of user station. Separate group broadcast available ( at most *0 groups)
  23. Patient card machine: the master station can connect to patient card machine, when a calling is happen from corresponding bed, the equal beds three color light of  patient card machine will keep flashing. There is card insert place on the patient card machine.
Display Telephone:the system support general telephone. It means that the calling information can be displayed from telephone display panel directly. The telephone should be customized 

País: China
N º de Modelo: CS800
Precio FOB: Obtener el precio más reciente
Lugar de origen: -
Precio de pedido mínimo: -
Cantidad de pedido mínimo: 1
Detalle de embalaje: carton box
El tiempo de entrega: 15 days against firm order
Capacidad de suministro: 10000
Tipo de pago: -
Grupo de productos : -

Send a direct inquiry to this supplier

A:

Mr. Ken < Asiamedi Technology Development Co., Ltd >

quiero saber: